Low Pressure from the Well

A reduction in pressure from the well can have several causes:
  1. the well going dry,
  2. a leak or blockage in a pipe in or from the well
  3. a pump problem
  4. a pressure tank or pressure switch problem
  5. an electrical problem (pump is running on 120 instead of 240)
Failure of the well itself is rarely sudden; generally there is a slow deterioration. However, during a drought it can seem to happen suddenly when the storage in the well itself is used up in the normal course of the day. If you have water at normal pressure first thing in the morning or when you get home from work, but the pressure seems to fall or the water run out after a little while, then you may have a groundwater supply problem.

While many wells will last decades, over time the amount of water a well yields can decrease. That can be caused by the water table falling due to extended drought, increased use or increased ground cover with roads, driveways, patios and houses in the recharge area. Mineral encrustation and reducing bacteria (often called iron bacteria) buildup can also decrease well recharge by plugging of holes in the well screen, plugging the piping or the filling of openings in the geologic formation itself. According to Penn State Extension the fall in well yield over time can be caused by changes in the water well itself including:
  1. Encrustation by mineral deposits
  2. Bio-fouling by the growth of microorganisms
  3. Physical plugging of groundwater aquifer by sediment
  4. Well screen or casing corrosion
  5. Pump damage
To provide a reliable supply of water at an adequate pressure for extended use, a drilled well must recharge at a rate greater than the typical domestic demand of 3-5 gallons per minute or have enough storage in the well itself to supply the demand. Each foot of a typical six inch well, has almost a gallon and a half of storage so that a 100 foot of well has 147 gallons. The crudest test of the well itself is to see if you can run it dry. My well is only 150 feet deep, but the static water level has fallen over the years to 43 feet below grade so running the hose (which draw about 3 gallons per minute) should draw down the well in about an hour. I ran the hose for 16 hours back in the spring an never ran it dry. It recharges faster than I was drawing water.

Even on the deepest home wells it would only take 5-6 hours to know if your well is not recharging fast enough and you can run your well dry. If you have more than about 150 gallons available in well storage it is generally enough to supply small household needs till the well can recharge. At that point it is more likely an equipment or system problem. You can potentially repair an encrustation problem (see https://greenrisks.blogspot.com/2020/03/keeping-your-home-supplied-with-water.html)

Equipment problems are the most common well problems. The first step is to check the equipment. The components of a modern drilled well system likely to impact pressure are: a submersible pump, the piping which can develop a leak or become clogged, a pitless adaptor,  the pipe to the house and the interior water delivery system including the pressure tank and pressure switch.

If your water supply has lost pressure, and seems to be drizzling out of your faucet or showerhead at all times, your problem could simply be a loss of pressure in the pressure tank or damage to or a leak in the bladder in the pressure tank. So start in the basement. The components within the basement provide consistent water pressure at the fixtures in the house and the electrical switch that turns on the pump. The pump moves water to the basement water pressure tank, inside the tank is an air bladder that becomes compressed as water is pumped into the tank. (There are other types of pressure tanks that do not have a bladder and a constant pressure pump does not need a pressure tank, but those installations are not as common.)

The pressure in the tank moves the water through the house pipes so that the pump does not have to run every time you open a faucet. The pressure tank typically maintains the water pressure between 40-60 psi or 30-50 psi for smaller tanks. After the pressure drops below the cut in pressure (typically 30-40 psi), the electrical switch turns on the pump and the pressure in the tank increases as the tank fills. If however, the pump is not delivering water fast enough the pressure tank could fail to regain its head while the water is in use. The pressure switch could also be the problem; it could be cutting in at the wrong pressure.

The first two things to check are the pressure in the pressure tank and your circuit breakers to make sure that the problem is not electrical. You can check the pressure on most pressure tanks with a tire gauge and the valve on the top. (Be sure to cut the power to the system and open a faucet to drain the tank before you measure the pressure. While the water is running out of the tank check the pressure on the pressure gauge, to make sure it is dropping and the pressure gauge is working). After thatyou’re your tier gauge to checking to see that the pressure in the tank is a couple of psi below the cut-in pressure set on your pressure switch. (Most are set to 38 psi for the 40-60 psi tanks.) When you unscrew the cover over the valve if water leaks out, your pressure tank bladder has failed, and it’s time to buy a new one.

The electrical switch in front of the the pressure tank (grey box under the gauge) turns on the pump. It is probably working since you have water, but check it anyway. Check the voltage before and after the switch just to make sure. When the pressure in the pressure tank falls to 40 psi (30 for small tanks) the switch at the pressure tank turns on the pump. Also, you can get what is essentially a vapor lock and the tank may simply need to be drained, bleed and recharged. Before you do that check to make sure that the tubing to the valve is not clogged.

When you turn the pump back on make sure that both circuit breakers are flipped to the on position. If there is a short in the pump system it can blow a single circuit. The pump can operate this way, but not very well. So turn off and on the pump’s circuit breakers or change the fuses. Pumps generally have two circuits tied together because an immersion pump draws a lot of power (240 volts). Make sure both circuits are on- a small water drizzle is one sign of a 240 volt pump getting only 120 volts. (If you know how to do it check the amperage across the pump to make sure it is steady and within range see the chart below from Franklin Electric.) In most cases the pump operates near the maximum load.

Time to look for problems outside. The pipe to the house or the pitless adaptor might have cracked. If like me your pipe runs under a portion of the driveway, this turns out to be a fairly expensive, but simple fix-excavating the pipe and replacing it. Look for signs that a pipe outside of the well is leaking, sinking ground, cracks in the driveway vegetation that looks a little too lush. If you end up replacing the pipe, make sure you slope it properly. If the horizontal well piping between well and building does not slope continually upwards or if it has a high spot, an air lock can form in the piping, so make sure if you end up replacing the pipe that it is properly slanted and not just a fixed depth below surface. The piping in the well itself can also develop leaks over time that can diminish flow.

If you do not see a leak from a pipe outside the well, you are going to have to look at the pump and equipment in the well. At this point, you are going to need help to identify the problem. It is more than a one man (or woman) job to pull a pump. Shallower pumps can be pulled by hand if you are a big, strong and young guy, but special equipment is necessary to pull a deeper pump even for a big guy in great shape. Call a well driller or a well repair company. The well drilling companies can generally replace, pumps and pressure tanks and other well components. In addition, they can diagnose an improper well design. Private well construction was not regulated in Virginia until the 1992 (though Prince William County had well regulations going back to 1979). I have seen some very odd well designs over the years. In Virginia a license is necessary to work on a well as a certified water well provider. Plumbers generally do not have this certification. Do not call a plumber for a well problem.

There are two types of pumps; a jet pump and a submersible pump. Most modern drilled wells are built with a submersible pumps. In older pump installations and dug wells, above ground jet pumps were often used, which can loose it prime. Both types of pump have a fitting called a foot valve. A foot valve is also used at the base of deep wells and is basically a check valve combined with an inlet strainer (older immersion pumps sometimes have what looks like a sock protecting the inlet). Both of these serve as a strainer to prevent picking up rocks or debris that could clog or jam the foot valve. They can get clogged and diminish flow.

Another possible problem is a leak or clog in the pitless adaptor. That is the fitting that allows the vertical well to connect to the horizontal pipe to the house below the frost line. Things like a leaky valve at the bottom of the well can result in a pump losing it prime after a power failure. The submersible pump is a long cylindrical unit that fits within the 6 inch diameter well casing. The bottom portion consists of the sealed pump motor connected to a series of impellers separated by a diffuser that drives the water up the pipe (which is black tubing in the picture) to the plumbing system through the pitless adaptor and a pipe that runs from the well beneath the ground to the basement.The piping or tubing within the well can fail or get clogged.



Finally your pump might be failing. According to the Water Systems Council a submersible pump should last 15 years or more, but silt, sand, iron bacteria and excessive mineral content can impact their life. A submersible pump operating high sediment water may fail in only a few years and a failing pump may appear as diminished pressure before complete failure.

If you need help with a well problem, the Wellcare® Hotline is staffed by the Water Systems Council (WSC), the only non-profit organization solely focused on private wells and small well-based drinking water systems. The Hotline operates Monday through Friday from 8:00 a.m. to 5:30 p.m. Eastern Time, and can be reached at 888-395-1033. Also, if you are in Virginia you can call or email the Virginia Master Well Owner’s Network for help.

Monday, August 16, 2010

Maintaining Private Wells and Personal Responsibility for Your Water Supply


While the U.S. Environmental Protection Agency (EPA) regulates public water systems, the responsibility for ensuring the safety and consistent supply of water from the estimated more than 21 million private wells belongs to the well owner. These responsibilities should include knowing the well’s history, testing the water quality annually (or more often as needed), and having the well system and its components inspected regularly by a well driller licensed or certified by the appropriate state agency where the well is located. In Virginia that is the Department of Professional and Occupational Regulation, DPOR.

Installation of private wells is regulated by various state agencies. State/local agencies that oversee private wells are usually responsible for approving the location of a well, inspecting the well after construction to verify proper grouting and adequate water yield, maintaining records of the well driller’s log, verifying the most basic pot ability of water by requiring at a minimum bacterial testing. In some regions of the country the Department of Health tests wells annually or at least did until the recent budget crisis. The well driller’s log should be reviewed by all homeowners (or potential homeowners). It identifies, the depth of the well, the depth of the casing, the types of soil and the, yield of the well. This will give you some indication of the characteristics of the aquifer.

A drinking water well that is contaminated could significantly impact your health and the value of your property. There is no requirement, but as one of the 15% of American families whose drinking water is supplied by a private well, I feel I should test my drinking water for all the primary and secondary contaminants of concern to the US EPA under the Safe Drinking Water Act. As the providers of our own water supply we need to serve as our own watch dogs, and ensure our safe water supply, no one else will. Part of the price of your own water supply is maintaining it and testing it. The local health departments have local rules and regulations for the installation of wells and can often help with testing for bacteria and nitrates which are the typical contaminants from septic systems, drain fields and livestock, but as the well owner you will need to take the initiative.

The water well test that was performed when you bought your house probably only tested for bacteria and nitrates, which is inadequate to be certain that your water is safe to drink. In addition, your water should be tested at least annually for those basic contaminants and after any flooding which might have impacted your well. The EPA recommends that you test your water well every year for total coliform bacteria, nitrates, total dissolved solids, and pH levels at a minimum. If you suspect other contaminants, test for those. Always use a state certified laboratory that conducts drinking water tests.

According to the Water Systems Council, you need to monitor the condition of the wellhead and inspect the well system annually. In their publications developed in partnership with the EPA they recommend that you routinely inspect your wellhead several times a year. Check the condition of the well covering, casing and well cap to make sure all are in good repair, leaving no cracks or other entry points for potential pollutants. Note any changes in condition. In addition, you should have the well system, including the pump, storage tank, pipes and valves, and water flow, inspected every 5-10 years by a qualified well driller or pump installer. The soil types, groundwater supply and materials of construction and depth of the well will determine the life of the well. Many wells can continue to produce water supply after a pump has failed and only need a new pump to return to service. This is especially true in areas of hard water where the well pump can have a relatively short life. If you notice a change in your water pressure, it may be time to have your system inspected. Do not ignore any changes in your water supply.

A drop in water pressure can originate in the pressure tank, the pressure switch, the pump or the well and water supply. A loss of charge in the pressure tank can be caused by a leak in the bladder or cause. Pressure to the tank is controlled by an electric switch that turns the pump on when pressure is low and off when the proper tank pressure is reached. A pressure switch can fail. In the well, a diminished water supply can be caused by drop in water level in the well due to drought or over pumping of the aquifer, or the well could be failing or a drop in pressure could be caused by a failing or damaged pump. Of course a drop in water pressure could just be caused by increased demand, if your pump is undersized for the number of plumbing fixtures in the house then using more than one bathroom at a time or doing laundry while hosing down the patio will cause a noticeable drop in water pressure.