Earlier this month the well owners who participated in the 2024 Prince William County Well Water Clinic received their results by email. Below you can see the summary of what was found in the 84-water analyses performed. VA Tech tested for the naturally occurring contaminants and common sources of contamination: a poorly sealed well or a nearby leaking septic system, or indications of plumbing system corrosion. These are the most common contaminants that affect our drinking water wells.
To determine if treatment is necessary, water test results should be compared to a standard-usually the U.S.EPA Safe Drinking Water Act (SDW) limits. Though private wells are not regulated by the U.S. Environmental Protection Agency (EPA) or the Safe Drinking Water Act, the SDW act has primary and secondary drinking water standards that we use for comparison. Primary standards are ones that can impact health and from the tested substances include coliform bacteria, E. coli bacteria, nitrate, lead, and arsenic. Secondary standards impact taste or the perceived quality of the water.
Just because your water appears clear does not mean it is
safe to drink. The 2024 Prince William County water clinic found that 27.4% of
the wells tested present for coliform bacteria. This is higher than last year.
Coliform bacteria are not a health threat itself; it is used to indicate other
bacteria that may be present and identify that a well is not properly sealed
from surface bacteria. The federal standard for coliform bacteria is zero, but
the federal standard allows that up to 5% of samples can test positive for
coliform during a month.
One of the bacteria contaminated wells tested positive for E
coli. Fecal coliform and E. coli are bacteria whose presence indicates that the
water is contaminated with human or animal wastes. Disease-causing microbes
(pathogens) in these wastes can cause diarrhea, cramps, nausea, headaches, or
other symptoms. These pathogens may pose a special health risk for infants,
young children, and those with compromised immune systems. However, people can
drink water contaminated with fecal bacteria and not notice.
If your well is contaminated with coliform but not fecal coliform or E. coli,
then you have a nuisance bacteria problem, and the source may be infiltration
from the surface from rain or snow melt. Typical causes are improperly sealed
well cap, well repairs performed without disinfecting or adequately
disinfecting the well, failed grouting or surface drainage to the well. Very
low levels of coliform (1-5 MPN) may appear in an older well during extremely
wet springs.
If your well was found to have coliform bacteria present you
should shock chlorinate the well (according to the procedure from VA Tech),
repack the soil around the well pipe to flow away from the well and replace the
well cap. Then after at least two weeks and the next big rainstorm retest the
well for coliform. If coliform bacteria is still present then a long-term
treatment should be implemented: using UV light, ozonation, or chlorine for
continuous disinfection. These systems can cost up to $2,000 installed (maybe
more with recent price increases).
If you have fecal coliform in the well or E. coli, your well
is being impacted by human or animal waste and you are drinking dilute sewage.
If there is not a nearby animal waste composting facility, then you are
probably drinking water from a failed septic system- yours or your nearest
neighbors or in some areas a leaking sewer line. To solve this problem you need
to fix or replace the septic system that is causing the contamination, replace
the well or install a disinfection and micro filtration or reverse osmosis
system. Giardia or Cryptosporidium are two microscopic parasites that can be
found in groundwater that has been impacted by surface water or sewage. Both
parasites produce cysts that cause illness and sometimes death. Chlorine can
work against Giardia but not Cryptosporidium. Ultraviolet (UV) light works
against both Giardia and Cryptosporidium so it is the preferred method of
treating this problem.
The failing septic systems can often be identified by using tracer dyes. While
continuous disinfection will work to protect you from fecal bacteria and E.
coli, be aware that if your well is being impacted by a septic system, then the
well water might also have present traces of all the chemicals and substances
that get poured down the drain. Long term treatment for disinfection, and
micro-filtration should be implemented: using UV light, ozonation, or chlorine
for continuous disinfection, carbon filtration, and anything that is used for
drinking should be further treated with a reverse osmosis systems or micro
membrane system both work by using pressure to force water through a
semi-permeable membrane. Large quantities of wastewater are produced by reverse
osmosis systems and need to bypass the septic system or they will overwhelm
that system creating more groundwater problems. Reverse osmosis systems produce
water very slowly, a pressurized storage tank and special faucet needs to be
installed so that water is available to meet the demand for drinking and
cooking.
Nitrate can contaminate well water from fertilizer use; leaking from septic
tanks, sewage and erosion of natural deposits. None of the wells in our group
of 84 samples had nitrate levels above the MCL. The regulatory limit for
nitrate in public drinking water supplies, 10 mg/L, was set to
protect against infant methemoglobinemia, but other health effects were not
considered and are emerging as problems. Nitrate in a well tends to climb
slowly over the years if the septic systems do not have at least 3 acres between
them. Based on a study done years ago in Dutchess County NY at least 3 acres
are necessary to naturally treat the nitrate.
Dr. Mary Ward of the Occupational and Environmental Epidemiology Branch,
Division of Cancer Epidemiology and Genetics, National Cancer Institute has
lead several important studies comparing all the research on the health impacts
from exposure to nitrate in water. The first review was of studies published
before 2005. In 2018 Dr. Ward was lead author on a review of more than 30
epidemiologic studies on drinking water nitrate and health outcomes. If
your nitrate-N levels are climbing, you might want to read Dr. Ward’s work. Thre
are AOSS systems designed to remove nitrate. These are very expensive (think
new care expensive.)
This year they found 3.6% of homes had first draw lead levels above the SDWA
maximum contaminant level of 0.015 Mg/L. After flushing the tap for at least
one minute none of the homes had lead levels above the 0.15 mg/L level;
however, many scientists do not believe that any level of lead is safe to drink
over an extended period of time. AndOften homes that have elevated lead in the
first draw, have lower pH values. Corrosive water is the primary risk for lead
in well water. However, over time water with a neutral pH could dissolve the
coating on galvanized iron, in brass
well components and plumbing fixtures.
Houses built before 1988 when the ban on lead went into effect and have low pH
water typically have higher lead concentrations. Lead leaches into water
primarily as a result of corrosion of plumbing and components in the well
itself but can also result from flaking of scale from brass fittings and well
components. Corrosion control techniques such as adjusting pH or alkalinity
that are commonly used to neutralize aggressive water will not work in to
reduce lead being leached from well components. For most instances, though, a
neutralizing filter and lead removing activated carbon filters can be used to
remove lead leaching from plumbing pipes, solder and fixtures. Recently, some
home water treatment companies are offering home treatment systems that
neutralize the water and add orthophosphate other phosphate solution to coat
the piping to prevent further corrosion of metal pipes. It should work if
maintained. This type of solution is used in public water supplies. I have no
experience with this type of home system and am not aware of any testing.
Iron and manganese are naturally occurring elements commonly found in
groundwater in this part of the country. 4.8% of the wells tested exceed the
iron standard and 3.6% exceeded the manganese standard. At naturally occurring
levels iron and manganese do not present a health hazard. However, their
presence in well water can cause unpleasant taste, staining and accumulation of
mineral solids that can clog water treatment equipment and plumbing and
discolored water. The standard Secondary Maximum Contaminant Level (SMCL) for
iron is 0.3 milligrams per liter (mg/L or ppm) and 0.05 mg/L for manganese.
This level of iron and manganese can be detected by taste, smell, or appearance.
In addition, some types of bacteria react with soluble forms of iron and
manganese and form persistent bacterial contamination in a well, water system
and any treatment systems. These organisms change the iron and manganese from a
soluble form into a less black or reddish brown gelatinous material (slime).
Masses of mucous, iron, and/or manganese can clog plumbing and water treatment
equipment.
All systems of removing iron and manganese essentially involve oxidation of the
soluble form or killing and removal of the iron bacteria. When the total
combined iron and manganese concentration is less than 15 mg/l, an oxidizing
filter is the recommended solution. (Iron bacteria, hydrogen sulfide and
tannins can also be removed with pre-chlorination.) An oxidizing filter
supplies oxygen to convert ferrous iron into a solid form which can be filtered
out of the water. Higher concentrations of iron and manganese can be treated
with an aeration and filtration system. This system is not effective on water
with iron/ manganese bacteria but is very effective on soluble iron and
manganese, so you need to do further testing to determine what type of
iron/manganese you have before you install a treatment system. Newer iron
filters have an option to add an ozone generator to kill reducing
bacteria. Water softeners can remove low levels of iron and
manganese and are widely sold for this purpose because they are very profitable
but are now being banned in some locations due to rising sodium and chloride
levels, what is known as inland salinization. Increasing salinization of our
water resources is a growing problem in our region. Also, water softeners are
easily clogged by iron bacteria.
Chemical oxidation can be used to remove high levels of dissolved or oxidized
iron and manganese as well as treat the presence of iron/manganese (or even
sulfur which was found in one well exceeding the EPA MCL) bacteria. The system
consists of a small pump that puts an oxidizing agent into the water before the
pressure tank. The water will need about 20 minutes for oxidation to take place
so treating before a holding tank or pressure tank is a must. After the solid
particles have formed the water is filtered. The best oxidizing agents are
chlorine or hydrogen peroxide. If chlorine is used, an activated carbon filter
is often used to finish the water and remove the chlorine taste. The holding
tank or pressure tank will have to be cleaned regularly to remove any settled
particles.
The pH of water is a measure of the acidity or alkalinity. The pH is a
logarithmic scale from 0 – 14 with 1 being very acidic and 14 very alkaline.
Drinking water should be between 6.5 and 8.5. For reference and to put this
into perspective, coffee has a pH of around 5 and salt water has a pH of around
9. Corrosive water, sometimes also called aggressive water is typically water
with a low pH. (Alkaline water can also be corrosive.) Low pH water can corrode
metal plumbing fixtures causing lead and copper to leach into the water and
causing pitting and leaks in the plumbing system. The presence of lead or
copper in water is most commonly leaching from the plumbing system or well
rather than the groundwater. Acidic water is easily treated using an acid
neutralizing filter. Typically, these neutralizing filters use a granular
marble, calcium carbonate or lime. If the water is very acidic a mixing tank
using soda ash, sodium carbonate or sodium hydroxide can be used. The acid
neutralizing filters will increase the hardness of the water because of the
addition of calcium carbonate. 16.7% of the wells tested were found to have
acidic water this year. One well had too high a pH. This is usually from over
treating with a water softener, but can be an expression of other pollution.
Water that contains high levels of dissolved minerals is commonly referred to
as hard. Groundwater very slowly wears away at the rocks and minerals picking
up small amounts of calcium and magnesium ions. Water containing approximately
120 mg/L can begin to have a noticeable impact and is considered hard.
Concentrations above 180 mg/L are considered very hard. Hard water can be just
a minor annoyance with spotting and the buildup of lime scale, but once water
reaches the very hard level 180 mg/L or 10.5 grains per gallon, it can become
problematic. Overall, 17.9% of homes tested had very hard water. (It is to be
noted that 53.6% of homes reported having a water softener.)
Two methods are commercially available (and certified) to
treat hard water. A water softener and a water system that work through a
process called template assisted crystallization (TAC), have been certified by
DVGW-W512 and are available in whole house units. In template assisted
crystallization, water flows through a tank of TAC
media. When the hard water comes into contact with the media, the magnesium
and calcium ions are caught by the nucleation sites. As more calcium and
magnesium ions build up within the sites, small micro-crystals form and flow
through your plumbing. They do not attach themselves to your water pipes as
scale.
The ubiquitous water softening system is an ion exchange
system consisting of a mineral tank and a brine tank. The mineral tank holds
small beads of resin that have a negative electrical charge. The calcium and
magnesium ions (along with small amounts of other minerals) are positively
charged and are attracted to the negatively charged beads. This attraction
makes the minerals stick to the beads as the hard water passes through the
mineral tank. Sodium from salt is used to charge the resin beads. The brine tank
is flushed out when the resin beads are recharged carrying the salty solution
to the environment. Inland salinization of surface waters and groundwater is an
emerging environmental concern. Research has shown that salinization has
affected over a third of the drainage area of the contiguous United States even
in areas without road salt. At the present time the EPA guidance level for
sodium in drinking water is 20 mg/L. Given the number of homes with elevated
sodium and our local geology, it is probably a reflection of the number of
homes with water softeners-50.0% of the wells tested had elevated sodium.
One of wells was found that had arsenic exceeding the EPA MCL for drinking
water of 10 ppm. While arsenic is a naturally occurring element found in soil
and groundwater it is not typically found at significantly elevated levels in
this geology. Arsenic is best removed by water treatment methods such as
reverse osmosis, ultra-filtration, distillation, or as a last choice ion
exchange (water softeners). Typically, these methods are used to treat water at
only one faucet. Though anionic exchange systems (water softeners) are whole
house systems, they may not be the best choice.
No comments: