Monday, August 13, 2012

Chevron Fire and Air Quality in the East Bay

On the evening of August 6, 2012 a fire broke out at the Chevron Refinery in Richmond, CA. The fire began in a crude oil unit, where there was a leak and was contained that evening, but a small controlled burn was allowed to reduce pressure in the system. Area residents were told to stay inside with windows closed for more than five hours before the all clear was given by the Contra Costa County Health Department.

The Bay Area Air Quality Management District (Air District) responded to the emergency and took eight air samples during the fire. After analysis of the samples for 23 chemical compounds the Air District reported that they found only acrolein levels above the Reference Exposure Level, REL. The Air District noted that throughout the Bay Area acrolein levels are commonly above the REL (not exactly comforting). Reportedly, acrolein levels routinely range between 1 and 4.5 parts per billion. The Air District stated in their news release that “(t)hese concentrations were similar to the “background” levels measured throughout the Bay Area by our monitoring network.”

While this sounds comforting this report by the Air District can be misleading. First of all the data is incomplete and second there are three types of REL, Acute (1 hour exposure), 8 hour (which may be repeated) and chronic. When the Air District spoke of REL they were referring to the acute level, not normal everyday background levels. According to Cal EPA “The acute REL is an exposure that is not likely to cause adverse effects in a human population, including sensitive subgroups, exposed to that concentration for one hour on an intermittent basis.” These health based acute RELs apply to spills, leaks, or other discharges to the ambient air that results from routine operation of a facility and predictable process upsets or leaks.”

Cal EPA determined the concentration level at which no adverse health effects are anticipated for a short term. The acute RELs are based on the most sensitive populations reporting of adverse health effects in the medical and toxicological literature. RELs are designed to protect the most sensitive individuals in the population by the inclusion of margins of safety. Margins of safety are incorporated into the REL to address data gaps and uncertainties, exceeding the REL does not automatically indicate an adverse health impact. The acute REL was the “background” levels that the Air District referred to. More importantly, the data from the Air District is not yet complete. There was no measurement of particulates.

According to reports in the San Francisco Chronicle there was a huge cloud of smoke and hundreds of people went to the hospital to seek treatment. The most likely source of health impacts from the fire is particulate matter from smoke. The Air District does not yet have any data to release on particulate concentrations downwind from the Chevron refinery. For some reason the stationary continuous particulate monitors for the Air District in the local area are upwind of the refinery. The Air District says samples were taken in San Pablo, two miles from the Chevron facility following the fire and are being analyzed for particulate matter levels. Results are expected in the next two weeks, but there is only a small chance that the regularly scheduled monitoring time will have caught the smoke cloud.

Particulate matter is made up of particles that are emitted directly, such as soot and dust, as well as secondary particles that are formed in the atmosphere from reactions of precursor pollutants such as oxides of nitrogen (NOx), sulfur oxides (SOx), volatile organic compounds (VOCs), and ammonia (NH3). Particle are either directly emitted or formed in the atmosphere. Directly-emitted particles come from a variety of sources such as cars, trucks, buses, industrial facilities, power plants, construction sites, tilled fields, unpaved roads, stone crushing, and burning of wood. Other particles are formed indirectly when gases produced by fossil fuel combustion react with sunlight and water vapor. Many combustion sources, such as motor vehicles, power plants, and refineries both emit particles directly and emit precursor pollutants that form secondary particulates. Ammonium nitrate and ammonium sulfate are the principal components of secondary particulates.

Particulate matter has immediate health impacts: itchy, watery eyes, increased respiratory symptoms such as irritation of the airways, coughing or difficulty breathing and aggravated asthma. Health effects can result from both short-term and long-term exposure to particulate pollution. Exposure to particles can also trigger heart attacks and cause premature death in people with pre-existing cardiac or respiratory disease. People most sensitive to particulate pollution include infants and children, the elderly, and persons with existing heart and lung disease. The particles can travel deep into the lungs, enter the bloodstream, and penetrate into cells. Smaller particles can penetrate deepest, causing the greatest harm. Researchers are still trying to identify which types and sources of particles are most hazardous to human health. Though, particles created from combustion soot tend to be fine particles with diameters smaller than 2.5 microns (PM 2.5) which are the most dangerous because it lodges in the lungs. Dust is mostly coarser particles.

According to the Lung Association, the two biggest air pollution threats in the United States are ozone and particle pollution. The United States Environmental Protection Agency, U.S. EPA requires states to monitor air pollution to assess the healthfulness of air quality and ensure that they meet minimum air quality standards. The US EPA has established both annual and 24-hour PM2.5 air quality standards (as well as standards for other pollutants). The annual standard is currently 15 ug/m3 (an AQI of 49). The 24-hr standard was recently revised to a level of 35 ug/m3 (an AQI of 99). The EPA is proposing new air quality particulate standards to go into effect in December 2012. The proposed annual average particle pollution will be lowered to 12-13 ug/m3. The maximum 24 hour standard will remain unchanged at 35 ug/m3. The Bay Area Air District does not have a live feed for their particulate pollution levels like some regions of the state.

The Bay Area's cool, coastal climate safeguards the region against some factors that exacerbate pollution, such as high temperatures and stagnant air flow. Nonetheless, the Bay Area is a nonattainment area due to persistent smog. Santa Clara, Solano and Contra Costa counties had more than 12 high particle pollution days last year of record. A study of children in Southern California showed lung damage associated with long-term particulate exposure, and a multi-city study found decreased lung function in children associated with long term particulate exposure. Many scientific studies have linked exposure to excess particulates to aggravated asthma, increased respiratory symptoms like coughing and difficult or painful breathing, chronic bronchitis, decreased lung function, heart attack and premature death. According to American Lung Association State of the Air Report, Pittsburgh, PA had the highest particle pollution in the nation on an annual basis and Bakersfield, CA had the highest number of days exceeding the daily level. Seven cities averaged particulate levels higher than the 15 ug/m3 current standard allows: Bakersfield, CA; Hanford, CA; Los Angeles, CA; Visalia, CA; Fresno, CA; Pittsburgh, PA; and Phoenix, AZ.

Thursday, August 9, 2012

Sinkholes In America

According to the Infrastructure Report Card from the American Society of Civil Engineers, New York’s waste water infrastructure needs an investment of $21.82 billion over the next 20 years to avoid failure. Just to emphasize the point in Bay Ridge Brooklyn not far from where I once lived in the 1970’s, the street suddenly caved in on August 1st and a 30 foot wide, 10 foot deep sinkhole appeared. This was the second sinkhole in this neighborhood of Brooklyn this year. The earlier sinkhole was twice as large. The city of New York immediately began repairs. According to the City, the sinkhole was caused by a 112 year old sewer pipe that gave way and washed away the soil under the road. The sewer pipe had no doubt been failing for a long time to erode that much soil.

Picture by CBS 2 Bay Ridge, Brooklyn sinkhole

The pipes made early in the 20th century were rated for an 80 year life span. New York sewer piping systems have reached the end of their design lives, but there are no plans of a replacement and upgrade of the system. There has been no systematic replacement program. New York has kept the sewer system alive by repairing what breaks after it breaks and spraying it’s mains with concrete. When the sewer systems were built in the 19th and 20th centuries, the Boroughs of New York still had autonomy and financed and built their own systems to address the problem in the least expensive way, by using a combined storm and sanitary sewer system. The Manhattan and Brooklyn systems were built around the same time modeling the designs of Hamburg, Germany. Nonetheless, the sewers were never designed for the ages, they need to be maintained and upgraded. New York and most of the United States has not maintained and upgraded our sewer systems. According to the U.S. Environmental Protection Agency, EPA, by 2020 half the sewer pipes in the U.S. will be crumbling and the U.S. risks reversing public health, and environmental gains of the past three decades.(Rose George in The Big Necessity, The Unmentionable World of Human Waste and Why it Matters.)

Failing sewer pipes can pose a significant threat to public health and the environment.  Systems with inadequate hydraulic capacity and/or blockages in the sewer pipes may lead to sanitary sewer overflows and sewage backing up into homes or onto streets.  Some of the health hazards associated with basement flooding by untreated wastewater include the potential presence of pathogenic microorganisms such as viruses, bacteria, and protozoa (in a nice moist dark environment). Pipe failures can be grouped into three general categories: hydraulic restrictions (e.g. blockage), hydraulic capacity, and structural condition.

Hydraulic restrictions are the most common problem in wastewater collection systems. Untreated wastewater carries sediment, grease, rags and whatever else you can think to put down the drain or flush down the toilet. The grease congeals with sediment and blockages form. In combined sewers, large items thrown or washed into the storm system create obstructions and restrictions during peak flow times. This can lead to street and basement flooding. Tree root intrusion, sediment accumulation, and grease build-up all contribute to hydraulic restrictions. Aging pipes that sag over time and joints that begin to fail can slow pipe flow and create more favorable conditions for solids to build up in pipes. An ongoing maintenance program for cleaning and flushing sewers is typically adequate to control blockages. However, budgeting for routine preventative maintenance and repairs has not taken place in New York or the rest of the United States. We fix it when it breaks.

Failure caused by inadequate flow capacity is common in combined sewer systems, but may also a sign of other types of problems such as structural defects or design defects. Major sources of pipe structural defects are cracks, broken pipes, and leaks. Pipes sag and sewage does not flow properly, areas of inadequate pipe slope can be due to loss of pipe bedding or inadequate initial slope. Structural failure as in Bay Ridge is typically caused by defects of the pipe wall and/or the soil envelope used to support the pipe.

The EPA reported that the total investment needs of America's publicly owned treatment works as of January 1, 2004, was $202.5 billion and increasing each year. Many systems besides New York have reached the end of their useful design lives, and the nation’s wastewater systems are no longer resilient in their ability to prevent failure, or restore service after a disruption. In addition, the electrical generation and distribution system, the energy sector, contributes to the lack of system’s resilience. Pumps and wastewater treatment plants do not operate without power and reduced reliability of the power supply is increasingly being addressed through the construction of dedicated emergency power generation at wastewater treatment plants and drinking water delivery systems.  Clean and safe water should be the national priority. If we had spent even a quarter of the  $821 billion of the American Recovery and Reinvestment Act of 2009 on the very unglamorous sewers and water treatment systems if the country we would have a cleaner environment, part of our infrastructure would be ready for another century and construction workers would have had jobs. 


Monday, August 6, 2012

NASA’s Curiosity Rover Lands on Mars

Curiosity Rover during a test at MSL


Last night at 1:32 am (eastern time) the rover Curiosity, a large mobile laboratory, was set down inside the Gale Crater by NASA’s Mars Science Laboratory, MSL, mission. The one-ton rover, hanging from a rocket backpack, touched down onto Mars after a 36-week flight using precision landing technology to place Curiosity in the crater. The MSL spacecraft that carried Curiosity succeeded in every step of the most complex landing ever attempted on Mars, including the final severing of the bridle cords and flyaway maneuver of the rocket backpack.

Now Curiosity begins a two-year investigation to delve into the secrets of Mars, the Red Planet. The rover will analyze samples scooped from the soil and drilled from rocks. The record of the planet's climate and geology is essentially "written in the rocks and soil" -- in their formation, structure, and chemical composition. The rover's onboard laboratory will study rocks, soils, and the local geologic setting in order to detect forms of carbon, the chemical building blocks of life on Mars. Curiosity carries a radioisotope power system that generates electricity from the heat of plutonium's radioactive decay. This power source gives the mission an operating lifespan on Mars' surface of a full Martian year (687 Earth days) or more and hopefully be able to gather enough data to assess what the Martian environment was like in the past.

Below is one of the first few images from Mars. According to John Grotzinger, project manager of NASA's MSL mission, at the California Institute of Technology in Pasadena. "In the image, we are looking to the northwest. What you see on the horizon is the rim of Gale Crater. In the foreground, you can see a gravel field. The question is, where does this gravel come from? It is the first of what will be many scientific questions to come from our new home on Mars." These first images of Mars are only half the size (in data) of the full-resolution Hazcam images that are expected to be sent back to Earth over the next several days. Check the NASA MSL site occasionally for new pictures and updates.
Gale Crater Mars August 6, 2012

Drought, Ethanol and the World Hunger Games


It is early August and the few acres of clover, weeds and grass that surround my house are once more green and growing. All through the spring and early summer I have kept a close watch on the water level in the U.S. Geological Survey, USGS, groundwater monitoring well up the road and read with anticipation each week Mark Svoboda’s of the National Drought Mitigation Center weekly report. The USGS has been continually monitoring groundwater levels at a nearby well since 1979 and posting the level daily. It has been unusually hot and dry and I watched the water level troughs in April and late June each followed by enough rainfall to bring the water level in the monitoring well (and I assume my drinking water well) to normal levels and increase the depth and flow of the creek in the woods at the bottom of my land. We have managed to avoid drought around here. The Midwest and much of the Great Plains have not been as lucky.

Most of the Midwest of the county has experienced above-normal temperatures with July coming in at 5-10 degrees above normal. Five to ten degrees! The region continues to be impacted not only by oppressive heat, but also drought. Not enough rain has left desiccated pastures and widespread crop damages, farmers are culling their livestock and the fire risk is elevated. The drought persists but some rain has fallen sporadically over the region. In The Great Plains drought has continued to expand and the temperatures remained 5 to 10 degrees above normal there, too.  The drought continues to advance across more of eastern Nebraska, southeastern South Dakota, Kansas, Oklahoma and the Texas Panhandle, stressing pastures, crops, livestock/wildlife, and trees. The one cheerful note is southeastern Texas, which has continued to recover from last year’s drought over the past several months. Overall, about 60% or more of the lower 48 states are experiencing some level of drought. Drought is not everywhere, but it is significant.

The National Agricultural Statistics Service (NASS) of the U.S. Department of Agriculture will release the yield and production forecasts for the 2012 U.S. corn and soybean crops on Friday, August 10th .  The U.S. corn crop is the largest in the world.  The USDA has been cutting its U.S. preliminary corn crop forecasts as the drought has progressed. Last word was that 45% of the corn crop is now estimated to be in poor or very poorcondition. Iowa the biggest corn producing state had 37% of their crops listed as in fair condition. This drought follows significant flooding last year in several parts of the county that reduced overall corn crop yields to under 12.5 billion bushels.

Congress has been deadlocked on passing a full farm bill because they don’t have enough support in the Senate for the five-year farm bill that came out of the House.  Instead with potentially half the corn crop  lost to the drought and pressure from cattle producers and other livestock producers who are worried about the cost of buying feed or culling their herds, the U.S. House passed a $383 million emergency relief package for livestock producers affected by the drought. The bill would have allowed payments of up to $100,000 per farm, for cattle and sheep ranchers but not hog and poultry farmers. Row crop farmers have insurance programs available to them, but the livestock programs expired in 2011 and this bill was an attempt to fill the gap. The Senate did not pass the drought measure before their five week recess on Friday and it was tossed into the pile of unfinished business.

In wet weather and dry weather we are the largest producer of corn in the world, but we have a problem that nature and Congress created together, The Renewable Fuel Standard, RFS, creating a regulatory mandated demand for corn. Last year the RFS mandated ethanol consumed 5.05 billion bushels of corn. Almost two thirds of the nation is in drought, and according to the most recent USDA report only 26% of the corn crop is in good or better condition, there are estimates that more than half of the corn crop is gone and still we have to meet the RFS.  The original United States Renewable Fuel Standard required that 7.5 billion gallons of renewable fuel (mostly ethanol made from corn) was to be blended into gasoline by 2012, but the program was expanded under the Energy Independence and Security Act (EISA) of 2007, which increased the volume of renewable fuel required to be blended into gasoline from 9 billion gallons in 2008 to 36 billion gallons by 2022. Last year, approximately 40% of the corn crop was used for making ethanol.

With half of this year’s corn crop potentially destroyed by drought added to last year’s flood reduced yield, and lower corn inventories; the RFS will make the crop situation worse by diverting most of the remaining corn crop into fuel leading to diminished supplies for livestock and food producers.  It is the unrelenting demands of the RFS against the livestock and food producers. We should not have to choose fuel over food or more likely have to import corn to feed our nation while we pay to convert corn into subsidized ethanol.

On Thursday, Bob Goodlatte of Virginia and 155 other member ofcongress sent a letter to Administrator Lisa Jackson of the U.S. EnvironmentalProtection Agency, EPA asking the Administrator to exercise her authority under the Clean Air Act section 211 (o) 7 to reduce the required volume of renewable fuel based on harm to the economy. This is a wonderful opportunity to actually live in harmony with nature and prevent the cost of food from rising even more and prevent us from taking food from the mouths of poorer nations. Yes, we can buy more corn if need be. The United States is a rich country and we will eat meat and the long list of food made from corn products. According to Tyler Cowen, professor of Economics at George Mason University, in his book, An Economist Gets Lunch, New Rules for Everyday Foodies, “(To put ethanol into gasoline) costs a lot more money than does traditional gasoline, once the cost of the subsidy is included. Sadly, it does not even make the environment a cleaner place. The energy expended in growing and processing the corn is an environmental cost too…the nitrogen-based fertilizers used for the corn are major polluters. Ethanol subsidies are a lose-lose policy on almost every front, except for corn farmers and some politicians.” “For millions of (people in poor countries) it is literally a matter of life and death and yet we proceed with ethanol for no good reason…(Biofuels) has thrown millions of people around the world back into food poverty.” Is it our goal to be the people of the Capital of Panem and have tributes from poorer nations play the Hunger Games? 

Thursday, August 2, 2012

Purchasing a Home with a Water Well-Caveat Emptor


In rural areas or here on the edge of nowhere private wells supply water to homes. If you are thinking about buying a home with a private water well you need to understand at a minimum the basics about groundwater, the local geology, water quality, how the well system works, how deep the well is and how old and what size pump it has. These are the factors that will impact water reliability, water quantity, and water quality.  It would be a real shame to discover after closing on home that the drinking water well does not supply enough water for you to do laundry in the summer, goes dry in a drought or that the water is contaminated or has an unpleasant taste or smell. It can be very expensive to replace a well or well components, engineer solutions to water supply problems and install and maintain a water treatment systems. A home inspection tells you nothing about the well or septic system.  

About 15% of households in the United States depend on private wells including over a million each in Virginia and Pennsylvania where I once lived. In its most basic sense a private water well is a hole in the ground that is drilled, driven, or hand dug to supply water for a household. Most wells today are drilled by a cable tool or by air-rotary drill. Hand-dug wells are usually very old but still exist; and are very susceptible to pollution from surface sources and may also present easy routes for surface contaminants to enter the aquifer. If considering purchasing a home with an old hand dug or driven well factor in the cost of replacing the well with a modern drilled well in the price and be aware that not all pieces of land have suitable aquifers to tap.

The aquifer is the groundwater. Aquifers may occur a few feet below the land surface, but useful aquifers are more commonly found at depths greater than 100 feet in Pennsylvania and 100-400 feet beneath the bedrock in Virginia. Some groundwater occurs in the pore spaces of solid rock, but most usable groundwater occurs in cracks and fractures in rock layers or between sand and gravel particles of unconsolidated layers. Except in Karst terrain which has its own special problem, groundwater normally occurs in small spaces within the geological layers and not as underground lakes or rivers.

 Geologic formations called aquitards are usually made of clay or dense solid rock. The aquidards inhibit groundwater infiltration, and restrict groundwater movement into and between aquifers. Aquitards located above and below an aquifer form a confined aquifer. If a well is drilled into a confined aquifer, artesian pressure forces the trapped water to rise in the well above the aquifer if the pressure is great enough, the water may even flow without pumping to the land surface creating an artesian well. The downside to a confined aquifer is that recharge is limited. The coastal plain in Virginia has a confined aquifer and is really only recharged at the “fall line.” A groundwater aquifer without an aquitard above it is an unconfined aquifer and more susceptible to contamination, but more easily recharged by precipitation. Without pumping, the water level in wells in unconfined aquifers is the same as the aquifer. The county department of health, the extension office, the local offices of the U.S. Geological survey are good places to find out about the local geological and groundwater conditions. You need to understand what type of aquifer you are dealing with to be aware of the factors that impact water quantity and quality. There are dry years and wet years and water availability will vary, though it is not always obvious. The groundwater aquifer tapped for water is not seen so you need to understand it to be aware of the water budget that you will have to live within before you run out of water.

In many locations private wells are not regulated or only minimally regulated. Virginia now has well drilling regulations and standards, but those only apply to wells drilled after 1992 and require a health department permit for drilling new wells and repairs of older wells.  If you buy a home with an existing well- buyer beware. It is your responsibility to make sure that you know what you are buying. The type of well, the well yield, the condition of the well and the quality of the water is your responsibility to determine before purchase. The type of well and the configuration will be determined by the age of the well and geology.  While there was a time when some wells were hand dug with a shovel or hand driven using connected pieces of pipe (as featured in Hallmark channel movies) most wells use equipment to drill, dig or drive pipe and by and large modern wells are drilled. Nonetheless, there are thousands of home supplied with water from older wells. Ask, look, investigate. Check driller’s logs filed with the health department.

The type of well is determined by geology and history. Sitting as my home does in the Culpeper groundwater basin above fractured rock and bedrock, drilled wells are predominant. When drilling a well, it is typical here and now in Prince William Virginia in the twenty-first century to drill the well through a first and second layer of groundwater. I have a second groundwater level I can drop my pump down to if need be in a drought.

Drilled wells penetrate about 100-400 feet into the bedrock. To continually supply water, a drilled well must intersect bedrock fractures containing ground water. The art of well drilling is having a feel for what a fracture looks like at the surface- knowing where the water is. A trained and experienced hydro-geologist can generally find the fractured rock zones, or the intersection of two fractured rock zones using aerial photography and the fracture trace technique. It can be expensive to hire a professional hydro geologist, but the cost is worthwhile for difficult areas.  Where I live in the Piedmont region of Virginia the local geology is a fractured rock system that is water rich with more than one groundwater layer, so using hydro geologists is not common, but I do know of a couple of instances where several wells were drilled before obtaining adequate water flow and it might have been more cost effective to locate water before the house was built or to design a different well system. The Piedmont tends to be so water rich that alternatives are not in common use. In some regions low production wells are common.

If a property has a low producing well, there are ways to deal with it. First is water conservation and the second is to increase water storage within the system. Water conservation involves changing water–use behavior such as taking shorter showers, but usually involves installing water saving devices like a front-loading washer (saves 20 gallons of water for each load),low flush toilets, flow restricting faucets and shower heads. Installing watersaving appliances can reduce household water use by up to 30%. Water conservation may solve the problem of a 5 gallon a minute well, but increasing water storage can make a reliable 1 gallon a minute well viable for a modern household. An intermediate storage system consisting of a storage tank ,reservoir or cistern that can be installed between the well and pressurized distribution system. The reservoir serves as the primary source of supply for the pressure pump supplying peak demand. Ideally, the storage tank or cistern should be able to hold at least a day’s water supply and be regulated by a float switch or water level sensor. A 1 gallon a minute well can pump 1,440 gallons per day more than adequate for a household of almost any size.  The rule of thumb is to size a storage tank or cistern at 100 gallons per person in the household. It is much cheaper to installed intermediate storage than keep drilling wells.   

Once you have determined that the water supply is adequate, the water quality should be checked. The quality of the groundwater is a characteristic of the aquifer and the ability of your local geology to protect or impact your aquifer. The most common sources of pollution to groundwater supplies come from two categories; naturally occurring ones and those caused by human activities. Naturally occurring contamination are produced from the underlying soil and rock geology. Microorganisms in the soil can travel into groundwater supplies through cracks, fissures, and other pathways. Nitrates and nitrites from the nitrogen compounds in the soil can also enter the groundwater. From the underlying rocks radionuclides and heavy metals can enter the groundwater. There are areas with natural occurring arsenic, cadmium, chromium, lead, selenium and fluoride. While many natural contaminants such as iron, sulfate, and manganese are not considered serious health hazards, they can give drinking water an unpleasant taste, odor, or color.

Human activities can also introduce contaminants into thegroundwater. Bacteria and nitrates can be caused by human and animal waste. Improperly constructed and sealed wells can allow surface contamination to enter the well. Improperly maintained septic systems containing human waste and any chemical you flush down the drain, horses, and backyard poultry can contaminate the groundwater. Leaks from underground storage tanks, surface disposal of solvents, motor oil, paint, paint thinner, termite treatment or nearby or historic landfills or industrial operations can contaminate groundwater. A confining geological layer can protect groundwater from surface contaminants more effectively than a fractured rock system, and there is extremely limited natural protection in karst terrain. Though it is cost prohibitive to test for every potential contaminant, a broad baseline analysis should be performed before purchasing a home (and every few years). A bacteria test is not enough. The cheapest way to do this is a commercial product aimed at the private homeowner. One product I have used is the WaterCheck with Pesticides. This product covers 15 heavy metals, 5 inorganic chemicals, 5 physical factors (like hardness and pH), 4 trihalo methanes, 43 volatile organic chemicals (solvents), and 20 pesticides, herbicides and PCB’s. The analysis takes two weeks and so the contingency period must allow for that or a more expensive analysis must be used. Whatever analysis you use, make sure you use an EPA certified laboratory that is also certified in the State where the property is located.

All private wells should be have as a water-tight, vermin-proof well cap and a cement or bentonite grout seal between the borehole and the well casing to prevent surface contamination and bacteria from entering the well. In coal or gas country, a well should include a vent. Well water should be tested annually to ensure a safe drinking water supply for your family. The supply of water should be adequate. In our modern world household water demand is not spread evenly over the day. There are peak usage times driven by washing machines, dish washers, showers. An adequate water system must be able to yield enough water to satisfy peak demand. Look for a minimum of 10 gallons a minute from a modern drilled well to supply a household or a system with intermediate storage (remember in some instances the well itself can provide storage). To live comfortably with your well, your water system has to be able to deliver an entire day’s worth of clear uncontaminated water within a 90 minute window.  

Monday, July 30, 2012

Dimock, Gasland and the EPA – Fracking and Water


Last Wednesday, July 25th 2012 the U.S. Environmental Protection Agency announced that it has completed its sampling of private drinking water wells in Dimock, Pa. Based on the outcome of that sampling, EPA has determined that the levels of contaminants present do not require additional action by the Agency, the water with the existing private well treatment systems is safe to drink. Regional Administrator, Shawn M. Garvin, said “The sampling and an evaluation of the particular circumstances at each home did not indicate levels of contaminants that would give EPA reason to take further action.  Throughout EPA's work in Dimock, the Agency has used the best available scientific data to provide clarity to Dimock residents and address their concerns about the safety of their drinking water.” The EPA’s news release is intended to end the story of Dimock, but bureaucratic speak is never really clear. So, let’s see if we can bring clarity and accuracy to the end of the story of Dimock, PA.  

The Safe Drinking Water Act, SDWA, which is how the EPA looks at water quality, defines a contaminant as “any physical, chemical, biological, or radiological substance or matter in water” (U.S. Code, 2002; 40 CFR 141.2). This is a very broad definition of contaminant includes every substance (including minerals) that may be found dissolved or suspended in water, everything but the water molecule itself. However, the SDWA only has MCLs and secondary standards for 91 contaminants. Groundwater aquifers are potentially vulnerable to a wide range of man-made and naturally occurring contaminants, including many that are not regulated in drinking water under the SDWA. The presence of a contaminant in water does not necessarily mean that there is a human-health concern. Whether a particular contaminant in water is potentially harmful to human health depends on the contaminant’s toxicity and concentration as well as other factors including the susceptibility of individuals, amount of water consumed, and duration of exposure. EPA did a final round of testing of the private wells in the Dimock area to make sure that the water from the drinking water wells was safe to consume and all identified contaminants were within the acceptable level as determined by a risk analysis. Most private well owners rarely test their well water quality and very few ever consider testing for the entire suit of contaminants regulated under the SDWA let alone the list of potential contaminants that EPA tested for here.

Dimock, Pennsylvania is located in Susquehanna County near the New York border, overlies the Marcellus Shale and was an early area that had been developed with hydraulic fracturing or fracking. Dimock had been made famous for its appearance in the Josh Fox movie Gasland.   In Dimock, Mr. Fox met families who demonstrated on camera how they were able to light their running tap water on fire due to the methane gas present in their wells. That was a rather spectacular display. Residents also claimed to be suffering from numerous health issues related to contamination of their well water. Methane is a simple asphyxiant that displaces oxygen from air. Methane released from water into an enclosed environment could cause serious symptoms. Exposure to low oxygen environments produces symptoms of central nervous depression, including nausea, headache, dizziness, confusion, fatigue and weakness. Even if there was no other contaminant of concern present in the water, the symptoms of central nervous depression could be very frightening.

Cabot began natural gas fracking in the Dimock area in 2008. On January 1, 2009, an explosion was reported in an outside, below-grade water well pit at a home located in Dimock. In Pennsylvania private drinking water wells are not regulated and are often the shallow, dug wells that are housed in a pit. The Pennsylvania Department of Environmental Protection (PADEP) collected samples from wells that provide drinking water to 13 homes located near the Cabot fracked gas wells, and these samples contained elevated levels of dissolved methane gas. (During the year the number of impacted homes would expand to 18 from 13.) The presence of dissolved methane and/or combustible gas was noted in the private wells within six months of completion of drilling of the Cabot  gas Wells and Cabot was presumed to be responsible for the pollution, pursuant to Section 208(c) of the PA Oil and Gas Act, 58 P.S. §601.208(c). None of the homes dependent on their private drinking water well had done any extensive testing of their water quality before Cabot began fracking in the area and all contaminants found (except for fecal coliform) are sometimes naturally present in groundwater. The two important questions raised were is the water safe to drink and did Cabot cause any change in the water quality by fracking in Dimock. PADEP presumed Cabot responsible and cited them for improper or insufficient cementing of the well casings. In addition there had been several other violations for improper storage of drilling mud, diesel spills, failure to maintain records and driller’s logs.

In November 2009 the PADEP entered into a consent agreement with Cabot for methane and metals removal systems for eighteen private wells in the Dimock area. The agreement was later revised several times. The revised agreement required Cabot to pay the impacted fam­i­lies set­tle­ments worth twice their prop­erty assessed val­ues, deposit the money into an escrow account and notify the residents that the money was available and to install a water treatment system (a filter or ion exchange system) in each impacted home. The agreement calls for each well owner to enter into the agreement with Cabot who was to install water treatment systems in their homes. Until the treatment systems were installed, Cabot was to provide delivered bottled water. There were no plans for confirmation testing to demonstrate the effectiveness of the filtration systems.  There were eighteen private wells that were part of the PADEP /Cabot agreement. By 2011 only six well owners had signed agreements and had water treatment systems installed in their homes. However, most of these were buying bottled water because they did not feel confident that the treatment systems were effective. Water treatment systems are often simple and unimpressive in appearance and verification sampling should have been performed.  Twelve of the private well owners had not signed the agreement Cabot and instead eleven (I could not trace the 12th ) had filed a civil suit against the company. These owners were being provided delivered water by Cabot. On November 30, 2011, with the approval of the PADEP, Cabot ceased delivering water to these homes. PADEP agreed to stopping the water deliveries because there had been sufficient time for residents to sign the agreement and that a remedy for private well owners had been provided. Clearly, many of the homeowners were not satisfied with the remedy offered.

Very public protests took place aided by environmental groups and anti-fracking grass roots groups and  resulted in the EPA stepping in and reviewing all the data for the 18 wells. In their summery EPA notes that based on the maximum contaminant sampling results for the 18 wells sampled, levels of coliform bacteria, methane, ethylene glycol, bis (2-ethylhexyl) phthalate (DEHP), 2-methoxyethanoI aluminum were present.  Coliform bacteria were found in half the wells and typically indicate a pathway exists for disease causing bacteria to contaminant the water supply, though it . E. coli bacteria and fecal bacteria are a subset of coliform bacteria that only occur in animal and human waste and are a threat to human health. The level of coliform bacteria found in two of the wells was too high to measure. After reviewing all the sample data, information and residents’ concerns by the EPA and ATSDR (a part of the U.S. Department ofHealth and Human Services) the regulators identified a significant group of private wells in the nearby area that had not been tested and were not part of the existing PADEP /Cabot agreement. In addition, the level of concern and frustration of the residents who were party to the PADEP /Cabot agreement prompted EPA to temporarily supply water to four homes and perform follow up environmental monitoring and water sampling and have ATSDR perform a full public health evaluation on the data from the site area. Because many of these compounds affect the same organ systems, ATSDR used suitable methods to evaluate the potential for synergistic actions and the cumulative concentration of all substances, and dissolved combustible gases was considered to protect against the buildup of explosive gases in all wells in the area.

Between January and March of 2012 EPA collected 61 separate groundwater samples, 6 duplicates for quality control testing and performed188 analyses for each sample, in some instances the samples were filtered and retested. These samples covered the water supply to 64 homes, and two rounds of sampling at four wells where EPA was delivering temporary water supplies because prior sampling data found elevated levels of contaminants in those wells. EPA found an elevated level of manganese in untreated well water at one of the wells. Two homes that obtain their water from that well have water treatment systems that can reduce manganese to levels that according to the EPA do not present a health concern.

Many of the perceived problems with well water are caused by the presence of iron and manganese. Iron and manganese can give water an unpleasant taste, odor and color. Manganese causes brownish-black stains on household items washed with the water. In addition, water contaminated with iron and manganese often contains iron or manganese bacteria which feed on the minerals. These bacteria do not cause health problems, but can form a reddish brown or brownish black slime in toilet tanks and clog filters. Iron and manganese often occur together and are naturally occurring elements commonly found in groundwater in many parts of the country. At  levels naturally present in groundwater iron and manganese do not usually present a health hazard. However, their presence in well water can cause unpleasant taste, staining and accumulation of mineral solids that can clog water treatment equipment and plumbing. In addition, a persistent coliform (non-fecal) bacteria problem may be caused by iron bacteria. Under guidelines for public water supplies set by EPA, iron and manganese are considered secondary contaminants. The standard Secondary Maximum Contaminant Level (SMCL) for iron is 0.3 milligrams per liter (mg/L or ppm) and 0.05 mg/L for manganese. This level of iron and manganese are easily detected by taste, smell or appearance and thumbing through the results of the EPA sampling I saw manganese levels high enough to see and taste in drinking water.

In addition, to the elevated manganese, there were elevated levels of sodium not beyond what can occur naturally, elevated levels of arsenic not beyond what can naturally occur, but in at least one case significantly elevated over the other samples and above the SDWA MCL. Methane was present in several samples and can also be naturally occurring. Fecal coiform bacteria indicative of contamination from a septic system was present in one sample (that water is NOT safe) and coliform bacteria was present in several samples. Only one of their sodium levels was higher than mine which is naturally occurring, safe to drink and tastes good.   

ATSDR performed the risk analysis on the results. Overall during the sampling in Dimock, EPA found elevated arsenic, barium or manganese, all of which are also naturally occurring substances, in well water at five homes at levels that could present a health concern according to ATSDR. In all cases the private wells either now have or will have their own treatment systems that can reduce concentrations of those metals to acceptable levels at the tap.  EPA provided all the residents their sampling results and has no further plans to conduct additional drinking water sampling in Dimock or continue to provide drinking water. The water supply to these homes with their treatment systems is deemed to be safe by the EPA.

The bottom line is we really do not know definitively what impact if any Cabot caused to the groundwater. Cabot agreed that they failed to properly grout the gas wells and certainly they did not properly store and contain the fracking fluid. Publicized photos show jugs of dirty looking water reportedly from wells in the area and could be manganese and iron, fecal contamination, or dirt that entered the groundwater through surface infiltration of loosening of fines within the aquifer. EPA sampling is silent on water appearance. PADEP concluded that surface spills and shoddy construction practices by Cabot allowed natural gas from a shallow deposit above the Marcellus to drift into the drinking-water wells of residents. The non-quantified traces of chemicals that are sometimes used in fracking, and antifreeze and are common in fuel that had been reported in previous sampling were not found the EPA water samples. EPA found only naturally occurring heavy metals at levels of any concern.

For the past decade and a half, the US Geological Survey, USGS, has been studying groundwater quality in the United States. The presence of a contaminant in water does not necessarily mean that there is a human-health concern. Whether a particular contaminant in water is potentially harmful to human health depends on the contaminant’s toxicity and concentration in drinking water. Other factors include the susceptibility of individuals, amount of water consumed, and duration of exposure that is why the ATSDR performed their risk analysis.  In their survey testing of groundwater in the United States the USGS has found most man-made contaminants at both trace and concentrations exceeding human health screening levels or MCLs in groundwater samples from unconfined aquifers. These man-made contaminants originate at the surface and the unconsolidated aquifers provided little natural protection from surface infiltration. 

The shallow drinking water wells in Dimock make them particularly susceptible to contamination. The residents of Dimock did not regularly test their water quality historically. The bacterial concentrations found in early rounds of testing were troubling, though unlikely to have been caused by the fracking, but were indicative of susceptible and potentially poorly maintained or constructed wells. The fecal bacteria found in one well was a health hazard very unlikely to have been caused by fracking, but likely to be caused by a failing septic system. Prior studies of private well water in Pennsylvania have found that approximately one third of private wells test positive for total coliform bacteria (Swistock et al 2009). The highest incidence of coliform bacteria tends to occur with snow melts and rains that carry the bacteria from the surface, but can also occur with iron and manganese. Regularly testing your drinking water and maintaining any water treatment system in your home is an essential part of private well ownership. 

Thursday, July 26, 2012

Blue Plaines From the Past to the Future

AECOM Picture


The District of Columbia's sewage system, one of the oldest in the United States, began its story around 1810, when the first sewers and culverts were constructed to drain storm and ground water from the streets of Washington D.C. In 1815 the canal system was built and included the Washington Canal that ran down what is now Constitution Avenue. The canal system provided a convenient way to transport goods, provide access to water and also dispose of waste. Residents drew their water from a series of city owned springs. In the first half of the 1800’s streets in Washington began piping in spring or well water for residents' use, and sewage was discharged into the nearest body of water- often the canals.

The Washington Aqueduct bringing river water for potable use citywide was built in the 1859 when population growth required a dedicated clean drinking water supply. Lieutenant Montgomery C. Meigs, is credited with planning and building the Washington Aqueduct. The surge in population during the Civil War, quickly created a human waste problem in the city and there were epidemics of smallpox, typhoid and malaria, which took many thousands of lives during the war years. From 1871 to 1874, the city’s Board of Public Works built an estimated 80 miles of sewers to remove the human waste from the city. Although the amount of construction was impressive, sewer engineering and hydrology were in their infancy and much of the work was poorly planned, structurally unsound and hydraulically inadequate, but the vitrified clay and brick sewers remain part of the sewer system to this day. In the early 1880s when the Washington City Canal was covered over because it had become nothing more than a stagnant open sewer, the problem of open sewage was transferred to the marshes along the Potomac and Anacostia Rivers.

Up to this time, the sewer canals and pipes that served DC were a combined system that merely carried and discharged (without treatment) both sanitary sewage and stormwater into local creeks and rivers. In the 1890s, it was decided that the existing combined system should be retained (due to the costs of rebuilding the sewers as separate systems), but that any extensions of the system would be built using the more expensive system of separate lines to carry stormwater and sewage flows. In order to protect the health of city residents, who were drinking the river water provided by the Washington Aqueduct, all the sewage discharges would be extended away from the city to a point far enough down the Potomac River to prevent being taken up in the Aqueduct for drinking water. The discharge point selected was Blue Plains, the southernmost tip of the District of Columbia. Pumping raw sewage into rivers was state of the art in the 1800’s. Washington DC did not start treating the sewage waste until 1937 when the Blue Plaines sewage treatment plant was built.

Today, sitting on the southernmost tip of Washington DC, across the river from Alexandria is the Blue Plains Advanced Wastewater Treatment Plant. While there are larger sewer treatment plants, that remove the solids and bacteria, the modern day Blue Plains also has Tertiary Treatment to remove nitrogen and phosphorus making Blue Plains the largest advance treatment plant in the United States at 150 acres and with a rated annual average day capacity if 370 million gallons per day (mgd) and a peak wet weather capacity of 1,076 mgd. The system needs such a large storm rated capacity to accommodate the old central city section which accounts for one third the area of the District and still has the old combined sewer system that overflows with predictable regularity during large storms. The system has released excess storm flows averaging 54 million gallons per year to the Anacostia River. In addition, Blue Plains is under a consent order from the Environmental Protection Agency, EPA, to meet new effluent limits for total nitrogen released and better control of the system during storms.

Being an advanced waste water treatment plant is not as modern as it sounds. At Blue Plains and other sewer treatment plants primary treatment screens wastewater, and performs some rudimentary treatment to remove crude solids of human waste and skim off grease, oil and fat. Wastewater sits in settling tanks, which are designed to hold the wastewater for several hours. During that time, most of the heavy solids fall to the bottom of the tank, where they become a thick slurry known as primary sludge. The material that floats is also skimmed from the surface of the tanks. Secondary (or biological) treatment involves feeding oxygen to bio-organisms that break down any organic matter still in the wastewater.

Tertiary treatment further treats the effluent water to remove nitrogen, phosphorus, fine suspended particles and microbes, and to kill or slowdown disease-causing organisms and viruses. It is the tertiary treatment that makes Blue Plains an Advanced Wastewater Treatment Plant. At this time, Blue Plains cannot remove enough nitrogen (on average over the year including storm periods) from the waste stream to meet the EPA mandated limit for nitrogen of 4.689 million pounds of nitrogen per year. In addition, when it rains and the Blue Plains AWWT plant tries to provide complete sewage treatment to flows of 600-740 million gallons a day the performance of the clarification units deteriorates because of the large flow of water, turbulence and not enough time to settle the solids and scum. The deterioration in performance cascades from the primary treatment to the secondary and onto the advanced treatment. This results in a reduced treatment for the sewage that lasts not only during the rain, but can last for several weeks. Blue Plans is currently engaged in a $7.8 billion 20 year improvement program called the Clean Rivers Project that will meet the reduced total nitrogen released requirements of their operating permits and increase the control of the system during rain storms in addition sludge treatment will be improved and sewer piping improved in many areas.

The sludge is separated from the wastewater during the primary treatment is further screened and allowed to gravity thicken in a tank. Then the sludge is mixed with the solids collected from the secondary and denitrification units. The combined solids are pumped to tanks where they are heated to destroy pathogens and further reduce the volume of solids. With treatment sludge is transformed (at least in name) to biosolids. Blue Plaines biosolids are Class B; however, after the completion of the improvement project in 2014 utilizing thermal hydrolysis (heating to over 160 degrees under high pressure) followed by anaerobic digestors, the biosolids produced by the plant will be Class A and the methane captured will provide 20% of the power for Blue Plains. To ensure that biosolids applied to the land as fertilizer do not threaten public health, the EPA created the 40 CFR Part 503 Rule in 1989 that is still in effect today. It categorizes biosolids as Class A or B, depending on the level of fecal coliform and salmonella bacteria in the material and restricts the use based on classification. The biosolids are tested for fecal coliform and salmonella and composite sampling is done for metals and hydrocarbons; the presence of other emerging contaminants in the biosolids is not tracked.

The Clean Rivers project will maintain the peak flow rate of 1,076 mgd from the collection system to Blue Plains. Peak flow rates to Complete Treatment would be reduced to 555 mgd for the first 4 hours, 511 mgd for the next 24 hours and 450 mgd thereafter. A tunnel would be constructed between Poplar Point and Blue Plains, and flows exceeding the complete treatment capacity would be diverted to the tunnel and that tunnel connected to the other tunnel storage. The storage provided by the new tunnel would be an additional 31 million gallons for a total storage in the system of 157 million gallons spread over the Anacostia River tunnels system and the new Blue Plains Tunnel. This facility will allow flow from the collection system that exceeds the complete treatment capacity of the plant to overflow to the tunnel. Flow captured in the tunnels would be dewatered through a new enhanced clarification facility, ECF, with a capacity of 225 mgd. Operating provisions would include arrangements to dewater the tunnels during and following rain and to convey ECF effluent to a direct outfall (after disinfection) and/or through the complete treatment facilities depending on the capacity available at the time.

The Clean Rivers project will also include the construction of Enhanced nitrogen removal, ENR, facilities. The new ENR facilities will have the capacity to provide complete treatment for flow rates up 555 million gallons per day for the first 4 hours, 511 million gallons per day for the next 24 hours and at a rate of 450 mgd thereafter to meet the new total nitrogen effluent limit mandated by the EPA. When completed, the Blue Plains Advanced Waste Water Treatment Plant will be able to meet the nitrogen release standard under the operating permit, reduce the number of uncontrolled storm related releases of waste.