Thursday, November 17, 2016

Lorton Quarry to Become Reservoir


At the end of October William Duke, President of Vulcan Materials Mideast Division, and Philip Allin, Chairman of Fairfax Water signed an agreement at a ceremony at the Griffith Water Treatment Plant in Lorton that sets the conditions for the transformation of a rock quarry into a water storage reservoir in southeastern Fairfax County.
from Google Maps

The Quarry will be converted to a reservoir in phases and continue to operate during phase 1 which will convert a portion of the quarry to a reservoir with storage of of about 1.8 billion gallons by 2035. Quarry operations will end with Phase II which will convert the remaining area to Fairfax Water reservoir with storage capacity of up to 15 billion gallons by 2085. To do this the existing quarry will be reconfigured to mine portions of Fairfax Water’s property. This will allow Vulcan to leave a “rock wall” that will segregate the quarry into the two parts. The two-reservoir Quarry reconfiguration addresses the water supply need projected to occur in the 2035-2040 timeframe.
from Fairfax Water

The Vulcan Quarry was identified as the favored alternative for meeting future water needs in the Northern Virginia Regional Water Supply Plan in 2011 and adopted by Fairfax County in early 2012. This new reservoir will be used to supplement water supply to accommodate population growth in Northern Virginia and ensure that Fairfax Water can continue to provide reliable, high-quality drinking water well into the future. 

Fairfax Water projects water need based on the most recent population and employee projections available from the Metropolitan Washington Council of Governments. Today, Fairfax Water serves nearly 2 million residents and more than 800,000 employees in Northern Virginia. Between 2010 and 2040, the population served by Fairfax Water, including wholesale customers, other communities that buy their water from Fairfax Water, is projected to increase by over 650,000 residents and nearly 550,000 employees. Fairfax Water needs to plan to reliably provide water to all.

All the regional water supply companies share the water resources of the Potomac. Fairfax Water, the Washington Aqueduct (WA) of the U.S. Army Corps of Engineers, and the Washington Suburban Sanitary Commission (WSSC), and the Interstate Commission on the Potomac River Basin (ICPRB) signed the Water Supply Coordination Agreement that established a framework for water supply planning, drought management, and resource optimization on the Potomac River back in 1982 and have worked together to manage the regional water resources since.

Every five years, the ICPRB conducts a study of projected demand and available water supply resources based on the best available information at the time- utilizes water use and demographic data along with assumptions regarding changes in water use patterns in the region. These are not certain. The ICPRB 2015 report assumes daily per capita water use will decrease by an additional 25%, incorporates various climate and weather scenarios and uses the projection of population growth provided by the Washington Council of Governments who forecast that the residential population is expected to grow by 23% and the workforce is expected to grow by 36% by 2040. They also looked carefully at the impact the climate change might have on water supply.


Historically, a key assumption was that the future flow of the Potomac River will mirror the hydraulic conditions for the past 79 years. If hydraulic conditions are changing or a 79 year period is inadequate to predict the possible extent of droughts, this could impact the availability of water. So, a couple of years ago the ICPRB engaged a study that created a model for various climate scenarios of water supply availability from Potomac Watershed to determine if the water supply would be adequate to serve the population. They used this model to examine the water supply adequacy of the current study.

The ICPRB found that the existing water supplies can meet demands of the forecasted population levels through the Year 2035, by implementing mandatory water restrictions during severe droughts. However, as the population and water demand continue to grow the current supply system including the Potomac River and all current and planned reservoirs and water storage would not be adequate to supply all needs during a severe drought even after using all the reservoirs to supplement flow and implementing water use restrictions.

This is why Fairfax Water has worked with Vulcan to develop the “two reservoir Quarry reconfiguration”, to provide interim water supply storage in 2035, as well as a significantly larger storage facility beyond 2085. With the delivery of the Northern Reservoir in 2035, Fairfax Water will be able to expand the Griffith Plant to 160 million gallons a day.  The Northern Reservoir will also provide an emergency source of supply to the Griffith water treatment plant when emergencies like chemical spills restrict the larger and newer Corbalis plant’s access to the Potomac River. This happened last year when Fairfax Water had to shut their intake to let a plume of contamination pass. 
 
  

Monday, November 14, 2016

Compare Air Pollution in New Delhi to Your Home

from US Embassy Feed
Air pollution in New Delhi has been in the news. According to reports from the Times of India, air pollution levels hit 999 micrograms of small particulates per cubic meter in some areas of the capital. For comparison in 2013 the U.S. Environmental Protection Agency announced the reduction in the fine particle pollution, PM2.5, average annual allowed level to 12 micrograms per cubic meter (ug/m3) or an AQI of 39. The 24-hr standard was recently revised to a level of 35 ug/m3 (an AQI of 99) and in truth not all cities in the United States currently meet that standard.

Last week the New Delhi smog was reported to be its worst in 17 years. The Government closed all of the city's more than 5,000 schools for three days to minimize the risk for children. In a city of over 17 million that meant that an estimated 4.41 million children missed three days of school according to the United Nations Children's Fund. The Air Quality index as measured by the PM2.5 monitoring station atop the US Embassy in New Delhi reported particulate pollution levels had fallen first to 400 then to 258 over the weekend, but the air quality is forecast to worsen again later this week.
Add caption


PM2.5 particles are a major contributing factor to lung disease. A study of children in Southern California showed lung damage associated with long-term particulate exposure, and a multi-city study found decreased lung function in children associated with long term particulate exposure. The United States particulate levels are a small fraction of the levels in the worst areas of the world-Beijing, New Delhi, Santiago (Chile), Mexico City, Ulaanbaatar (Mongolia), Cairo (Egypt), Chongqing (China), Guangzhou (China), Hong Kong, and Kabul (Afghanistan).

PM2.5 particles can be either directly emitted or formed via atmospheric reactions. Primary particles are emitted from cars, trucks, and heavy equipment, as well as residential wood combustion, forest fires, and agricultural waste burning as is still common in India. The main components of particulate pollution formed when pollutants like NOx and SO2 react in the atmosphere to form particles. These particles are emitted from coal fired power plants and other combustion engines. The increase in automobiles and coal fired power plants in both India and China has exacerbated this problem in India, China and other areas of the world because particulates can travel great distances.

So, as the Indians and Chinese spew more and more pollutants and particulates which are most concentrated in their own cities but are worsening in many cities around the world. As the Indians and Chinese expand their air pollution, the United States continues to reduce ours. If you want to take a look at real time particulate pollution levels you can see what the monitors nearest your home are reporting. Long Park in Haymarket Virginia was reporting an AQI level of 2 as I was finishing this article. Long Park is about 3 miles from my house down route 15.

Thursday, November 10, 2016

5 Second Rule is Bunk

Though it was “busted” by the Myth Busters years back when they were still on the air, researchers at Rutgers University School of Environmental and Biological Sciences (extension), Professor Donald Schaffner and his graduate student Robyn Miranda recently put the “5 second rule” to rigorous scientific test. The “5 second rule” is the popular notion that food dropped on the floor, but picked up quickly, is safe to eat because bacteria need time to transfer.

Bacterial cross-contamination from food coming into contact with surfaces can contribute to foodborne disease. The cross-contamination rate of Enterobacter aerogenes was used as a proxy for disease carrying bacteria and measured on household surfaces of stainless steel, tile, wood and carpet. The food types were watermelon, bread, bread with butter and gummy candy. The transfer times tested were under 1 second, 5 second, 30 second and 300 seconds. Transfer scenarios were evaluated for each surface type, food type, contact time and bacterial prep; surfaces were inoculated with bacteria and allowed to completely dry before food samples were dropped and left to remain for specified periods

What the researchers found was that bacteria can transfer essentially immediately on contact with food that is dropped; and the wetter the food, the higher the risk of transfer― watermelon had the most contamination, gummy candy the least. Also, longer food contact times usually result in the transfer of more bacteria from each surface to food

All totaled 128 scenarios were replicated 20 times each, yielding 2,560 measurements. Post-transfer surface and food samples were analyzed for contamination. The researchers concluded that the longer food was in contact with a surface the in more bacterial transferred, they also found that other factors are to be considered such as the nature of the food and the surface it falls on, are of equal or greater importance. Surprisingly, they found that carpet has very low transfer rates compared with those of tile and stainless steel, the transfer rate from wood is more variable. “The topography of the surface and food seem to play an important role in bacterial transfer,” Dr. Schaffner said. “Bacteria don’t have legs, they move with the moisture, and the wetter the food, the higher the risk of transfer. Also, longer food contact times usually result in the transfer of more bacteria from each surface to food.”

The bottom line is that contamination can transfer almost immediately. It is essential to clean your working surfaces and floors regularly to prevent cross-contamination of food on your counters, and don’t eat whatever it was that fell on the floor, throw it out. Donald Schaffner is a professor and extension specialist in food science at the School of Environmental and Biological Sciences, Rutgers University-New Brunswick. Robyn Miranda is a graduate student in his laboratory there. Their study appears online in the American Society for Microbiology’s journal, Applied and Environmental Microbiology (only the abstract is free).

Monday, November 7, 2016

You Can View High Resolution Land Use Data

For the last several years the Chesapeake Bay Program Office of the U.S. Environmental Protection Agency (EPA) has worked with local governments and their partners in all 206 counties within the Chesapeake Bay watershed across six states and the District of Columbia. All the Chesapeake Bay watershed counties and major municipalities have gathered together information on local land cover, land use, parcel and zoning data and converted it to a consistent format so that it could be accessed and used by the EPA.

Thanks to the hard work of groups like our own Prince William Soil and Water Conservation District and the Prince William County Government local land use data was collected from over 80% of counties. In parallel with these activities, the counties and municipalities funded the development of new high-resolution data on land cover—such as impervious surfaces, tree cover and water—for the entire watershed. This work was carried out by the Chesapeake Conservancy, the University of Vermont and World View Solutions, mapped out land cover across more than 80,000 square miles at a one-square-meter resolution. This is amazing resolution. This land cover data was then combined with the information provided by the various local governments and agencies to produce a detailed land use dataset for each county.

Now the EPA has used the high-resolution mapping of land use to update and improve the EPA Chesapeake Bay Program’s Chesapeake Bay Watershed Model, used to measure success against the EPA mandated Chesapeake Bay restoration activities and support local, state and regional decision making across the region. The latest version of this model, Phase 6, is currently under review. The EPA mandated a contamination limit for nutrient contamination and sediment to all the states in the Chesapeake Bay Watershed and Washington DC. The EPA set a total limit for the entire watershed of 185.9 million pounds of nitrogen, 12.5 million pounds of phosphorus and 6.45 billion pounds of sediment per year which was a 25% reduction in nitrogen, 24% reduction in phosphorus and 20 % reduction in sediment from the 2011 levels. The pollution limits were then partitioned to the various states and river basins and counties based on the Chesapeake Bay computer model and monitoring data. The problem with the first versions of the model was the land use data and impervious ground cover data was not consistent across different parts of the model.

The pollution limits were created by a series of models of the Chesapeake Bay Watershed. These computer models are mathematical representations of the real world that estimate environmental events and conditions. The models are at best imperfect, but they are nonetheless the best tool available to view the 80,000 square miles of the watershed. The Chesapeake Bay and its watershed are so large and complex, that scientists and regulators rely on computer models for critical information about the ecosystem’s characteristics and health, then use the model to assess the impact of various environmental mitigations to reduce pollution.

The earlier versions of the model had used approximately 675,917 acres for the impervious surface data and 1,885,915 acres for the pervious surface data in Virginia. A review of the EPA’s own data found that there were 1,569,377 impervious acres and 3,442,346 pervious acres in the urban areas in the Virginia segments of the model that includes all the paved and landscaped areas of suburbia. Between the 1990 census and the 2010 census when the model was developed the population of Virginia grew from 6.2 million people to 8.0 million people. The bulk of that growth took place in the urban and suburban centers of the Chesapeake Bay watershed. This served to distort the model and resulted in the under reporting of pollution from impervious surfaces (like roads, buildings and parking lots). Pollutions loads for nitrogen, phosphorus and sediment in the urban areas are calculated using a constant pounds/acre/year for impervious acres as a fixed input, and the pervious load is based on total fertilizer sales data less the impervious load. The under reported acres of housing and roadways distorted the agricultural contribution to the pollution by increasing it. Hopefully in the latest version of the model, that has now been corrected.

The datasets will be made available free-of-charge to local governments and the public over the next month or so. In addition, local governments will make available the data they collected on past land cover and land use over the last 30 years, as well as map overlays with geographic coverages of federal lands, sewer service areas, regulated stormwater areas and combined sewer overflow areas within each county. At the moment, Prince William and the rest of the Virginia counties are all still pending, but should be ready for viewing shortly at http://chesapeake.usgs.gov/phase6/ also the beta version of the Chesapeake Bay Model can be viewed at this link. 

from the EPA Chesapeake Bay Program

Thursday, November 3, 2016

WSSC Tries New Pipes

The Washington Suburban Sanitary Commission (WSSC) provides water and sewer service to 1.8 million residents in approximately 460,000 households and businesses in Prince George’s and Montgomery counties in Maryland. Established in 1918, WSSC is one of the largest water and wastewater utilities in the nation, with a network of about 5,600 miles of fresh water pipeline and over 5,400 miles of sewer pipeline. Unfortunately, over many years the maintenance and replacement of the piping systems was deferred.

Approximately 1,300 miles of the more than 5,600 water mains are more than 50 years old. Nearly 2,500 water mains are between 25 and 50 years old. Almost 1,800 miles of water main were installed in the last 25 years. The age of the piping reflects more the age of the buildout of the system than any maintenance and replacement, for decades the only pipe replacements were for failed piping. After decades of deferred maintenance water main breaks have grown in frequency to about 2,000 breaks a year. Though age is not the only factor that causes pipe failure, most of the system’s pipes were designed for an average lifespan of 70 years. Over the next 10 years WSSC projects they will have to replace over 2,000 miles of water pipe and similar amount or sewer pipes. WSSC estimates that water pipes cost about $1,600,000 per mile of pipe.

Now WSSC is introducing new pipes that feature a zinc-coating on the exterior, which protects against corrosion. This is an improvement on the previous industry standard of uncoated ductile iron pipes that are exposed to soil. The zinc coating increases the life of iron pipes. Charged zinc ions migrate to scratched areas naturally, so pipes are less susceptible to corrosion damage than those composed of other materials. Additionally, the new piping will also have a V-bio® enhanced polyethylene encasement wrap, which discourages the growth of harmful bacteria that can damage the pipe.

Traditional ductile iron pipe lasts about 50-75 years the new pipes have a projected lifespan of well over 100 years, based on experience in Europe. Zinc coating on ductile iron pipe has been in widespread use in Europe where the industry first began using zinc coatings in 1955. As a result of zinc's widespread use there, standards were both developed and widely adopted. The advances in zinc coatings over the past 60 years have resulted in a highly effective corrosion inhibiting pipe that is now also coated in a V-bio polywrap.

The wrap protects the iron from a fresh supply of oxygen, thus halting or greatly inhibiting the corrosion. The patented V-Bio prevents microbiological cells from forming that would attack the iron and deplete the zinc. It is believed that the use of V-Bio with the presence of zinc as an anode to iron will further slow the process, though field tests in the United States have so far been about 10 years. The new pipe costs slightly more than the older style pipes, but since installation is the bulk of the cost the total price per mile is estimated to increase to $1,620,000 from $1,600,000. A reasonable cost for what WSSC hopes will be decades of additional service.


Though recently, WSSC has been replacing about 55-60 miles of water mains per year that has not been enough to keep up with the aging system that suffers from decades of deferred maintenance and some problematic piping. That rate of pipe replacement would replace the water system in 101 years, but much of the system has already exceeded their design life and some pipes in the WSSC system have not been lasting as long as originally projected.

Most of WSSC was installed after World War II in the booms of the 20th and 21st centuries. Post-World War II pipes tend to have an average life in the real world of 50-105 years depending on many factors (AWWA). To extend the life of the ductile pipes they were mortar-lined. These linings were meant to prevent corrosion and increase pipe longevity. In the 1970’ steel reinforced concrete pipe with a promised life of 100 years began to be used for the giant water mains by WSSC. Unfortunately, these concrete trunk lines began to fail catastrophically decades before their promised 100-year life expectancy.

WSSC has 350 miles of steel reinforced concrete pipe. WSSC ‘s supplier, Interpace, may have produced inferior pipe- the company was successfully sued by WSSC and others and is now out of business. Nine of the WSSC’s concrete mains have blown apart since 1996. After a particularly spectacular blowout 2008 and to prevent future catastrophe, WSSC installed a sensor system along all the concrete mains that cost more than $21 million to alert WSSC of an impending failure, but unfortunately the replacement program became an emergency replacement program responding to sensors and smaller breaks. Now the new program hopes to improve this situation, but with 1,300 miles of piping over 50 years old it is likely that the number of water main breaks will get worse before it gets better. Remember most pipes break in the winter months, so be prepared for emergencies and store an adequate emergency supply of water in your home- 10 gallons per person should be a three day supply.

Monday, October 31, 2016

Wind Generated Power 2016


Since the last time I looked at the share of total U.S. electricity generation by wind mills it has risen significantly. Wind facilities produced 190,927 gigawatt/hours (GWh) of electricity in 2015, or 4.7% of net U.S. electric power generation. The level of wind's generation has doubled since 2010, when the share was 2.3%. Based on monthly data through July, wind has provided 5.6% of U.S. generation in 2016.

The increase of wind power in the United States has been driven by a combination of technology and policy changes. Technological changes include improved wind technology and increased access to transmission capacity. Financial incentives and policies such as the Federal Production Tax Credit (PTC), Investment Tax Credit (ITC), and state-level renewable portfolio standards (RPS) have pushed utilities and investment groups to build more wind capacity. The PTC that grants a federal tax credit on wind generation, while the ITC allows federal tax credits on wind farm investments. State RPS, meanwhile, require that a minimum percentage of electricity generation comes from renewable energy.

The bulk electric system of the Lower 48 states consists of three independently electric interconnections: Eastern, Western, and the ERCOT part of Texas. Because of minimal transfers of electricity between the Interconnections, each interconnection essentially meets its demand with its own generating resources and utilizes the available generating power sources. Despite incentives, most of the wind generation takes place in the center of the nation where prevailing winds are strongest.



In 2015, 11 states generated at least 10% of their total electricity from wind. In 2010, only three states had at least a 10% wind share. Iowa had the largest wind generation share, at 31.3%, and South Dakota (25.5%) and Kansas (23.9%) had wind generation shares higher than 20%. Two additional states, Texas and New Mexico, are on track to surpass a 10% wind generation share in 2016, based on data through July. Wind generation in Texas, the highest wind electricity-producing state, made up 24% of the national total wind generation and 9.9% of Texas's total electricity generation in 2015.

Thursday, October 27, 2016

5 Counties Offer Financial Assistance in Maintaining Septic Systems

At the last housing census about 28% of Virginia households had septic systems. This is a bit higher than the average of 25% for all U.S. households. It is widely accepted, but not well documented that improperly managed septic systems contribute to major water quality problems. In 2003 EPA reported that 168,000 viral and 34,000 bacterial illnesses occur each year from drinking water contaminated by waterborne pathogens from fecal contamination due primarily from failed septic systems. Unfortunately, many homeowners are unaware of how septic systems work, what is necessary to maintain them, or lack the financial resources to properly maintain their systems.

Now for five counties in Virginia- Orange, Madison, Culpeper, Rappahannock and Green- financial assistance is available to all residents with septic system. Through a grant funded by the Commonwealth of Virginia, the Culpeper Soil and Water Conservation District is offering financial assistance to all residents in their 5 county conservation district to pump septic tanks, fix septic system malfunctions and perform preventative maintenance. This program will reimburse participants who sign up before the work is done up to $150 for a septic system pump-out and 50% of any required repair or replacement expenses, including full system replacement. For low income households up to 75% of the cost of a septic system replacements or new installations can be reimbursed.
* up to 75%  is available for low income households


This money could allow residents in Orange, Madison, Culpeper, Rappahannock and Green counties to get their tanks pumped and septic systems repaired. Proper maintenance of septic systems (both traditional and alternative) is essential for protection of public health and local water resources and maintaining the value of your home. The regulations for septic systems are limited. For traditional systems located within a Chesapeake Bay Preservation Area once a system is built, the responsibilities for the owner are to have the system pumped out at a minimum every five years. However, there are no regulations that require the inspection of a traditional system, so you may not know your system is no longer functioning properly. For alternative septic systems called AOSSs there are more requirements including annual inspections. Here is a little tip, systems are less likely to back up into your basement or percolate out of the drain field if you pump them out frequently.

The drain field does not have an unlimited capacity. The more water your family uses, the greater the likelihood of problems with the septic system, so it is important to fix all leaks, and stop toilets from running and practice water conservation. In the Chesapeake Bay watershed many homes are within areas designated resource protected areas that requires a septic tank pump out at least every five years, but that may not be frequent enough depending primarily on the size of your tank, the number of people in the household contributing to the volume of your wastewater, the volume of solids in your wastewater and whether you use a garbage disposal or have a water treatment system. Excess water flow through the septic system can cause the solid sludge buildup and floating scum (grease, oil, dead skin cells, etc.) to flow out of the tank and travel into the leach field area. Some newer systems have screens and filters to keep solids from entering the leach field. These filters and screens become clogged and need to be cleaned out regularly or the system will back up into the house.

The septic tank is a buried, watertight container typically made of concrete, fiberglass, or polyethylene. It holds the wastewater long enough to allow solids to settle out (forming sludge) and oil and grease to float to the surface (as scum). It also allows partial decomposition of the solid fecal materials. Anaerobic (without oxygen) digestion takes place with the aid of bacteria that came from human digestive tracks and most of the fecal solids are converted to carbon dioxide, water and other byproducts. The process is not completely efficient and fecal solids and other materials that find their way into the septic tank will accumulate over time. To keep a septic system operating optimally, a septic tank must be pumped every few years to remove the scum and solid layers. Steady use of water throughout the day and water conservation should be practiced because too large a flow of waste water and the solids in the tank will be stirred up and be carried out to the drain field.

If you are in the five counties of Orange, Madison, Culpeper, Rappahannock and Green and have a septic system call the Culpeper Soil and Water Conservation District for more information at 540-825-8591 or 540-948-7531.