Thursday, September 13, 2012

The Doctor and His Septic System


I was waiting in a doctor’s exam room when he arrived with friendly banter about a sport I had no knowledge of due to lack of interest. I laughed and said he should try a topic I was interested in or knew something about. Kidding, I suggested we talk about groundwater or septic systems. He immediately launched into the horrifying story of how he operates his septic system and his concerns about its operation. He apparently had lived in his house for 15 years and never once pumped his septic tank. Instead he had two drain fields which he switched between every six months and dutifully poured septic system additives down the drain every month. He had been using some “granules” but now was pouring a “blue liquid” and was worried about the new liquid. He had no idea of the basics about septic system operation and maintenance, and no idea about what he had probably done to his system. The good news is that neither he, nor his neighbors are using the groundwater and he has adequate money to fix his system. So, this is for a certain wonderful doctor who shall remain nameless. (By the way, dear doctor, you can build a fabulous new alternative septic system for less than the cost of a new mid-range luxury sedan. That is the upper end of what fixing your problems will cost.)
Failing septic system from NCDH presentation

A typical septic system has four main components: a pipe from the home, a septic tank, a leach or drain field (alternative systems might have drip fields, sand mounds or peat tanks where a leach field is not possible or has failed), and the soil. The septic tank is a buried, watertight container typically made of concrete, fiberglass, or polyethylene. It holds the wastewater long enough to allow solids to settle out (forming sludge) and oil and grease to float to the surface (as scum). The septic tank also allows partial decomposition (by natural bacterial action) of the solid fecal matter. Compartments and a T-shaped outlet in the septic tank are intended to prevent the sludge and scum from leaving the tank and traveling into the leach field area. Some newer systems have screens and filters to keep solids from entering the leach field, but older systems typically do not. These filters and screens can become clogged and need to be cleaned out regularly to prevent septic sludge from backing up into the house.

Septic tank wastewater flows (by gravity or pump) to the leach field, where it percolates into the soil, which provides final treatment by natural soil filtration which removes harmful bacteria, viruses, and nutrients. Suitable soil is necessary for successful wastewater treatment. Microbes in the soil can digest or remove most human produced biological contaminants from wastewater before it eventually reaches groundwater. There are also Alternative systems (or AOSS) that have additional treatment tanks or components like peat moss tanks or sand filters to assist in the filtration process. For a septic system to work properly, the waste stream cannot contain too much solid material or scum. High quantities of solids in the waste stream will overwhelm the leach field. Initially, nitrogen and fecal bacteria will be released to the groundwater as the soil becomes saturated with solids and scum. Eventually the perforations in the pipes to the leach field through which waste water flows can become clogged and the waste may ultimately backup through the system into your home or surface in the yard.

To keep a septic system operating optimally, a septic tank must be pumped every few years to remove the scum and solid layers. Steady use of water throughout the day and water conservation should be practiced because too large a flow of waste water and the solids in the tank will be stirred up and not settle and be carried out to the drain field. Also, the drain field does not have an unlimited capacity. The more water your family uses, the greater the likelihood of problems with the septic system. Finally, you need to limit what goes down the drain to prevent bacterial die-off in the tank so that it will continue to function as designed. Die-off of the bacterial necessary for a septic system to perform properly has been seen in experiments where excessive amount of harsh household chemicals were added to the septic tank. As little as of 1.85 gallons of liquid bleach, 5.0 gallons of liquid Lysol cleaner, or 11.3 grams of Drano drain cleaner added to a 1,000-gallon septic tank have caused die-off of the bacteria in experiments. Other factors that can cause die-off include the excessive use of anti-bacterial agents, and, in certain cases, antibiotic medications taken by members of a household.

However, in normal use, you do not need to add a chemical or biological stimulator or an enhancer to a septic tank that is designed, operated, and maintained properly. The naturally occurring bacteria are already present within human fecal matter are adequate for the system to function properly. Contrary to popular belief, chemical additives, such as caustic hydroxides and sulfuric acid, should never be added to a septic system. Adding these chemicals will destroy the bacterial population in the septic tank, change the permeability characteristics of the soil absorption system, and may cause groundwater contamination.

Often, manufacturers of biological additives market their use to restore the bacterial balance in a septic tank on a monthly basis as part of a routine maintenance program. As mentioned above this is not necessary because these bacteria are already present in human feces. These kinds of additives are thought to be harmless to the functioning of a system. A lack of need has not stopped manufacturers from advertising their products. However, some studies indicate that enzymatic products might have the ability to reduce the amount of oil and grease in the septic tank, but the oil and grease flows out of the tank to the soil. The scum layer in a septic tank “holds” fats, grease, and floatables, preventing their escape to the drain field. Enzymatic products can “break up” this scum layer and increase its mobility, allowing it to enter the soil absorption system. So you save on pumping your septic tank and instead slowly destroy the functioning of your drain field.

Manufacturers’ claims that septic additives either eliminate the need for pumping of a septic tank or can restore permeability of the soil absorption system are entirely unsubstantiated according to Cornell University. No product has been demonstrated to allow a homeowner to escape regular septic tank pumping and maintenance, but can contribute to the premature failing of a soil absorption system. The drain field has a limited lifetime and capacity. After a few years, the solids that accumulate in the septic tank should be pumped out and disposed of at an approved location. If not removed, these solids will eventually overflow, accumulate in the drain field, and clog the pores in the soil and the openings in the pipes. While some clogging of soil pores occurs slowly even in a properly functioning system, excess solids from a poorly maintained tank or a tank where enzyme additives were used instead of pumping the tank can completely close all soil pores so that no wastewater can flow into the soil. The sewage effluent will then either back up into the house, flow across the ground surface over the drain field, or find another area of release in the septic system. If this happens, you may need to construct a new drain field on a different part of your lot or install an alternative treatment system like peat tanks or sand filters. Pumping the septic tank after the soil drain field has become completely clogged will not rejuvenate the system only alleviate the surfacing of waste water until the tank fills up again. I am intrigued by the idea that the Doctor’s alternating drain fields every six months might have slowed the clogging of the drain field by allowing it to rest for half of each year. Usually, a second leach field is installed when the primary field is failing and used this way when the second leach field developed problems also. 
From NC Department of Health presentation

In some cases where the drain field has become clogged and no longer can adequately absorb the wastewater, the toilets and sinks might not drain freely. A black residue may remain at the bottom of the toilet.  If the drain field can absorb the effluent, but no longer treat it, the sewage may contaminate the groundwater or surface water with fecal coliform bacteria and it could take a long time to identify that problem unless you and your neighbors are using the groundwater as a drinking water supply and test your water. Contaminated groundwater often looks and tastes just fine. If your drain field has become clogged, but is not backing up into your home there are several other signs: The ground near the drain field or other section of the septic system maybe wet or mushy, even during dry weather. The visible liquid in these wet areas is often dark (sometimes nearly black).The area around the failure may have a distinctive odor and flies are often attracted to the failure (especially in the hotter season). The lawn may grow greener in these areas. The grass is a brighter green over a failing drain field, distribution valve or other failed component.

While I know my doctor would never try to disguise a failing septic system in selling his home, not all people are as honorable. Before buying a home with a septic system, have it inspected by a licensed individual or Professional Engineer specializing in septic systems and knowledgeable about local geology and soils. If the property is also on well water thoroughly test the water quality, also. Though commercially available dyes and tracers can be used to confirm a suspected problem, they will not identify all septic system failures, due to the type of failure (releasing untreated waste water into the subsurface) or due to intentional masking of the problem. If you pump a septic tank it will take several days or more than a week (depending on the size of the tank and household) for water to be released to the drain field again. That is generally more than enough time for the wet areas of the yard to dry out and will keep the tracer dyes from being seen in the yard.

Commercially available dyes and tracers are best used to establish the flow path of wastewater and confirm a suspected problem. Dyes and tracers are most efficiently used to confirm cross-contamination of wells by nearby septic systems. They can be used to identify which of nearby septic systems is the source of a well contamination problem much less expensively than a DNA test on the waste bacteria (oh yeah, with enough money you can do that, too).  Tracking of sewage effluent in groundwater and surface water systems is complex and difficult to predict using dyes and tracers. Just because the dye or tracer does not appear does not mean that untreated sewage is not contaminating surface and groundwater systems or that a septic system is working properly.

Monday, September 10, 2012

The Water Footprint of Humanity


I have seen the statement that 90% of water used globally is used for agriculture, more and more frequently. This “new” statistic has replaced the often quoted World Health Organization statement that 80% of freshwater used is for irrigation. The WHO number is based on measurement of water withdrawals from rivers and groundwater for irrigation. The 90% number (it is actually 92%) is from a recent paper by Arjen Y. Hoekstra and Mesfin M. Mekonnen of the University of Twente in the Netherlands titled “The Water Footprint of Humanity.” They estimated the consumptive use of rainwater for agricultural production and add that amount of water to groundwater pumping and surface water diversion to examine the consumptive use of water for agriculture.  Thus, the 90% of water used globally refers to an estimate of how much irrigation water and rainfall water is consumed  by crops and agriculture in general.

The Water Footprint has no relationship to the rainwater available and does not relate in any way to the sustainability of surface and groundwater use patterns. In all countries the amount of water in agricultural products accounts for the largest proportion of water used. According to their methods agriculture accounts for 92% of the water footprint, industry 4.4% and domestic use (the water we drink and bath with) accounts for 3.6%.  I’m not at all sure that utilization of rainwater in watering crops a meaningful measurement of water use. It leaves unaddressed sustainability of water use, the importance of (or lack of importance of) the rainfall on woodlands, recharging of groundwater that is not being depleted, stormwater runoff and other rainwater uses. It almost implies an ownership of rainwater that falls in various lands. The purpose of the work was to develop a global water management tool, but does not address the complicated aspects of water that is at times renewable and other times not.

In an attempt to look at water beyond the watershed these two Dutch scientists in a series of studies have attempted to trace the concept they called the Water Footprint, by including data on rainwater use and volumes of water used for human and animal waste assimilation to track waters movement in water-intensive commodities as they move across the globe. By importing food, a country externalizes their water footprint.  The scientists identified the water content of various foods by estimates based on global precipitation, temperature, crop, and irrigation maps and the yield, production, consumption, trade and wastewater treatment statistics for nations. There are assumptions underlying this data on planting and harvesting dates per crop per region, feed composition per animal and country as well. In addition the scientists assumed that industrial water supply are spread according to population densities.

Arjen Y. Hoekstra and Mesfin M. Mekonnen then estimated the water content of all products and determined a trade balance with water content in a product as the measure. Using their methodology the major gross virtual water exporters are the United States, China, India, Brazil, Argentina, Canada, Australia, Indonesia, France and Germany. The scientists note that “all these countries are partially under water stress, which raises the question whether the …choice to consume the limited national (surface and groundwater) resources for export is sustainable and most efficient.” Good question. These scientists were trying to develop a way to look at the global dimension of freshwater resources to try to understand and ultimately solve the most pressing and urgent water problems, addressing the limits on the supply of and contamination of fresh water on the planet, and the ability of the planet to feed themselves. However, their operating framework ignores comparative advantage (French wine) and seems to suggest that water in agricultural products is not properly valued. However, they cannot actually determine what the country limit to agricultural production is because they have not addressed the limits of water supply, and unsustainable use of water.

Let’s look at this from another angle.  All the water on earth is over 4 billion years old. “It's one of the more astonishing things about water — all the water on Earth was … here when Earth was formed, or shortly thereafter…in the first 100 million years or so. There is, in fact, no mechanism on Earth for creating or destroying large quantities of water.” The quote above is from Charles Fishman’s book, The Big Thirst: The Secret Life and Turbulent Future of Water. All the water that ever was or will be on earth is here right now. More than 97% of the Earth’s water is within the in oceans. The remaining 2.8% is the water within the land masses. The land masses contain all the fresh water on the planet. Of the land surface water, 77% is contained in icecaps and glaciers and for all practical purposes is inaccessible in the short run, and on a warmer planet will not be stored in ice. The remaining fresh water is stored primarily in the subsurface as ground water with a tiny fraction of a percent of water is stored as rivers and lakes which are renewed by rainfall.

Only a fraction of water falls as rain each year to make the rivers flow, recharge lakes and groundwater. The water on earth never rests, it is constantly moving within the hydrologic cycle along various complex pathways and over a wide variety of time scales. Water moves quickly through some pathways -rain falling in summer may return to the atmosphere in a matter of hours or days by evaporation. Water may travel through other pathways for years, decades, centuries, or more—the groundwater stored in the Wasia aquifer in Saudi Arabia fell from the atmosphere as rain thousands of years ago. In the Middle East, in California, in India and throughout the planet we are using groundwater faster than it is being recharged. We are using up our stored water reserves to grow food and the water reserves are shrinking. So, that determining the water footprint in the way that Arjen Hoekstra and Mesfin Mekonnen have attempted does not convey the limited time that mankind can continue to use water in the way that we are using water now.  

As of 2010, 783 million people worldwide still relied on unimproved water sources (surface water from lakes, rivers, dams, or unprotected dug wells or springs) for their drinking, cooking, bathing and other domestic activities. In 2004 (the last year for which statistics were available), water, sanitation and hygiene was responsible for 1.9 million annual deaths from diarrhea. Most diarrhea deaths in the world (88%) are caused by unsafe water contaminated by human or animal waste, sanitation or hygiene. In addition, there are estimated to be as many as one billion hungry people in the world, some even in the United States.

The earth has a fixed amount of land and water. Water is complicated by the variability in weather and the variable length of different parts of the water cycle. Precipitation does not fall in the same amounts throughout the world, in a country, or even a region and varies from year to year. We are on a trajectory towards a world where ever increasing numbers of people will not have food security and will starve during drought years.  Farmers in the United States feed 20% of the world’s population on just 10% of the earth’s surface that is how we ended up the largest virtual water exporter. The U.S. agricultural sector is the most successful in the world, but will not be able to meet the world’s projected food demand and we may not want to mine groundwater in California to export Almonds. California might want to drink some of that water. Even if all the world’s farmers adopted conservation-based agricultural production techniques (emphasizing soil health) there are limits to what the earth can reliably produce each year. During a “good” period of temperature and rainfall in the most agriculturally productive areas and the most marginal areas the world’s population and demand for food will grow to exceed the average production and the next drought or the exhaustion of a groundwater aquifer will bring catastrophic consequences. It has always been the nature of man (see the Mayan Empire).

According to the Dutch scientists, over a fifth of the nations are net water importers, they have an external water footprint. Many highly water scarce countries (that can afford it)  are externally water dependent- Kuwait, Jordan, United Arab Emirates, Israel, Yemen, Malta, and Cyprus. Though, not all countries with a large external water footprint are water scarce. One of the interesting observations was that the Netherlands and United Kingdom are net importers of food and thus water.   Arjen Y. Hoekstra and Mesfin M. Mekonnen state “For governments in water-scarce countries such as in North Africa and the Middle East, it is crucial to recognize the dependency on external water resources and to develop foreign and trade policies…” to ensure a sustainable and secure import of water intensive commodities (food). It is not viable to irrigate crops with desalinated water.  According to the US Geological Survey it takes 20 gallons of water (on average) to grow one apple, 4,000 gallons of water to grow one bushel of corn, 11,000 gallons of water to grow one bushel of wheat, 15,000 gallons of water to raise a cow. The Dutch scientists finish by pointing out that China with  a relatively internal water footprint is leasing lands in Africa to secure their food supply and water resources outside their country.

Thursday, September 6, 2012

Maintaining 24/7 Water in America


From the American Water Works Association 2011

In most of our communities and cities we inherited the water infrastructure which was built by previous generations. This water storage, treatment, and distribution system delivers as much water as we want whenever we want it (under most circumstances). This amazing infrastructure to deliver 24/7 water was built beginning in the late 19th century and throughout much of the 20th century. We have barely thought twice about our water and have taken for granted the capital investment made by those previous generations. The water bill that most pay barely covers the cost of delivering the water and some repairs.  No infrastructure lasts forever and we have failed to properly maintain and plan for the orderly replacement of the water distribution systems. In the United States we have never experienced the need for pipe replacement on a large scale and have taken for granted what we were given. However, in our cities water mains are failing at an ever increasing rate.

The water distribution systems in most of our big cities have reached the end of their useful life. As documented by the U.S.Environmental Protection Agency Drinking Water Needs Survey and Assessment 2007  and the American Water Works Association, AWWA, report: “Buried No Longer:Confronting America ’s Water Infrastructure Challenge” a large proportion of US water infrastructure is approaching, or has already reached, the end of its useful life. The need to replace or rebuild the pipe networks that deliver water comes on top of other water investment needs, such as the need to replace water treatment plants, upgrade treatment technology to respond to emerging contaminants in our raw water supplies, replace storage tanks and on-going monitoring and compliance costs. The investment needs for our wastewater and stormwater systems will also have to be addressed for those systems are old as well.

According to the AWWA, restoring existing water systems as they reach the end of their useful lives and expanding them to serve a growing population will cost at least $1 trillion over the next 25 years in 2010 dollars, if we plan to maintain 24 hours per day on demand of water service for our country. The AWWA analysis includes investments that will be necessary to meet projected population growth, regional population shifts, and service area growth over that period. The EPA estimates that the twenty-year capital improvement needs for infrastructure investments necessary from 2007, through 2026, for the existing water systems to continue to provide safe drinking water to the public to be $335 billion assuming no growth in service area and no population shift. EPA’s “Clean Water and Drinking Water Infrastructure Gap Analysis,” actually estimated drinking water systems’ 20-year capital needs in the range of $204 billion to $590 billion with a point estimate of $335 billion, the always cited cost. The EPA costs exclude maintenance and replacement of dams and reservoirs because they are excluded from the EPA’s Drinking Water State Revolving Fund, DWSRF, funding. The smallest systems actually have the highest cost per person for pipe replacement because the residences are more spread out- there are more feet of pipe main per residence and the EPA’s data may be weakest in that category.

The EPA estimate for total national need of $335 billion in 2007 is comparable to the 2003 estimate of $331 billion (as adjusted to 2007 dollars). Indicating that no progress has been made in the long term replacement and during the period 2003-2007 only repairs seem to have been made.  Both the 2003 and 2007 EPA Assessments and the AWWA assessment clearly point to the nation’s water systems having entered a “rehabilitation and replacement era in which much of water utilities’ existing infrastructure has reached or is approaching the end of its useful life.” It is to be noted that no real progress has been made in water infrastructure replacement since 2007.

We are living with aging drinking water infrastructure, with increasing incidence of unplanned failures. We can continue to respond to water emergencies or, we can carefully prioritize and undertake drinking water infrastructure renewal investments to ensure that our water utilities can continue to reliably and cost-effectively support the public health, safety, and economic vitality of our communities. The choice is ours and will be made community by community. According to the EPA, water utilities in the United States is highly fragmented with approximately 52,000 water systems with 56% of that number serving populations of 500 or less. The large number of relatively small systems may not have the expertise to analyze a system and develop a replacement plan and may not have the financial capability to raise capital independently. However, smaller systems can more easily vote for capital surcharges and may be eligible under the DWSRF. The Safe Drinking Water Act, as amended in 1996, established the DWSRF to make funds available to drinking water systems to finance infrastructure improvements. The program emphasizes providing funds to small and disadvantaged communities and to programs that encourage pollution prevention as a tool for ensuring safe drinking water.

How will all this money be spent?  Transmission and distribution pipes, pumps and valves represent about 60% of the projected cost of replacement and rehabilitation. Although the least visible component of a water system, the buried pipes of a transmission and distribution network generally represent most of a system’s capital value. Even small rural systems may have several hundred miles of pipe. In larger cities, replacement or rehabilitation of even small segments of the extensive underground networks of water supply pipes can be very costly, due not only to the cost of construction but also the costs related to disruption to the city’s traffic and business. Replacement projects for water mains, valves and pumps present such challenges that they are typically only undertaken after failure driven by a utility’s need to continue providing potable water to its customers while preventing contamination of the water prior to delivery.

The rate at which water mains fail varies greatly by type of pipe, age of the pipe, water characteristics, soil characteristics, weather conditions, and construction methods. Some pipe materials have been found to degrade prematurely; galvanized pipe has turned out to be particularly susceptible to corrosion in certain soils, and unlined cast iron pipe is susceptible to internal corrosion. Asbestos cement pipe presents challenges to protect workers during pipe repairs. Currently, many water systems are using ductile iron or polyvinyl chloride pipe (PVC) for construction and replacement now. It remains to be seen how long this infrastructure will last.

The EPA estimates that 22% of the costs of water infrastructure rehabilitation will have to be spent on treatment and compliance.  Treatment facilities vary across systems depending on the quality of their source water and type of contamination present. Treatment systems can range from a simple chlorination for disinfection to a complete conventional treatment system with coagulation and flocculation, sedimentation, filtration, disinfection, laboratory facilities with computer automated monitoring and control devices. This also includes projects to remove contaminants that affect the taste, odor, and color of drinking water, but are otherwise harmless (or almost so). These costs may increase due to deterioration of source water quality.

Source water infrastructure is estimated at about 6%. This includes constructing or rehabilitating surface water intake pumps and pipes, drilled wells, and spring collectors. Drinking water comes from either ground water or surface water sources. Wells deliver groundwater. Rivers, lakes, and wells in karst terrain under the direct influence of surface water are considered surface water sources. A high-quality water supply can minimize the possibility of microbial or chemical contamination and may not require extensive treatment facilities. Many of the source water needs involve construction of new surface water intake structures or drilling new wells to obtain higher quality raw water to minimize the treatment costs.

The remaining 12% of water infrastructure needs are attributed to storage and miscellaneous other projects. Storage includes projects to construct, rehabilitate, or cover water storage tanks, but it excludes dams and raw water reservoirs because they are specifically excluded from DWSRF funding. A water utility cannot function without sufficient storage to provide adequate supplies of treated water to the public, particularly during periods of peak demand. This storage allows the systems to maintain the minimum positive pressure required throughout the distribution system to prevent the intrusion of contaminants into the (deteriorating) distribution networks which are not “water tight.”


Monday, September 3, 2012

Update on Endocrine Disruption in Water Supplies

From USGS paper cited below

Earlier this month Vicki Blazer of the U.S. Geological Survey published a new paper, “Indicators of Reproductive Edocrine Distruption in Fish in the Chesapeake Bay Watershed.” Dr. Vicki Blazer is a mairine biologist and researcher at the U.S. Geological Survey, USGS. Dr. Blazer received the American Fisheries Society 2010 Publications Award for her article investigating the mortality of fish in the Potomac River basin and is a fish biologist at the West Virginia Science Center studying the impact of contaminants of emerging concern in rivers and streams of the lifecycle and health of fish on the Chesapeake Bay and its tributaries. This paper is a summary of the most recent research (previously published) by the USGS and others on endocrine disruption in fish in the Chesapeake Bay watershed and the implications to our lives.

The Chesapeake Bay watershed feed the Chesapeake Bay, the largest and most productive estuary in the United States. It serves as a nursery ground for the fish and shellfish industry and protects the coast from storm surges and filters pollution. The estuary filters water that is carrying nutrients and contaminants from the surrounding watershed. The nutrients in proper balance bring fertility, but excess nutrient contamination to the Chesapeake Bay has caused degradation in the habitat and impact to fish and other animals. As a result, US EPA has taken control of the situation and has developed a new federally mandated TMDL (total maximum daily load) to try to restore the natural balance in the estuary by controlling nutrients in the local waters. The TMDL addresses pollution from phosphorus, nitrogen and sediment and allocates a pollution budget among the states which will decrease over time. However, according to Dr. Blazer, the fish (and other aquatic organisms) in the Chesapeake Bay watershed are being exposed to a complex mixture of chemicals that may have additive, synergistic or antagonistic effects.

In the Potomac River watershed, largemouth bass show signs of feminization (testicular oocytes and vitellogenin in males) but appear to be less sensitive than smallmouth bass to the effects of estrogenic compounds. The scientists discovered that the smallmouth bass have both a higher incidence of intersex (male fish with eggs) occurrence and a high incidence of skin lesions and large fish kills in the Potomac and James Rivers. Smallmouth bass may be the most sensitive indicator of environmental health in the Chesapeake Bay watershed. The smallmouth bass is a warning that should not be ignored, but the pollution problem they represent are beyond our understanding at this time. More work needs to be done.

Although feminization of male fish has most commonly been associated with exposure to human wastewater-treatment-plant effluent, the prevalence of male smallmouth bass with intersex characteristics is not consistently higher downstream from these point sources than upstream in the areas of the Potomac River watershed that were studied. It is not simply the residue of birth control pills in human waste. However, some additional biomarkers, such as the ratio of gonad weight to body weight and plasma vitellogenin concentrations in female bass, do appear to be adversely affected by the presence of wastewater-treatment plants upstream from the study site, but more is going on.

The sources of the endocrine-disrupting chemicals associated with intersex smallmouth bass appears to be BOTH effluent from wastewater-treatment plants and runoff from agricultural land, animal feeding operations, and urban/suburban land. All impacts of mankind. Other factors, including wastewater-treatment-plant effluent flow, number of animal feeding operations, and number of poultry houses were also associated with an increased intersex severity. Within the Potomac River basin the data showed that the higher the human population density the higher the incidence of intersex in the smallmouth bass. Also, the higher the percentage of agricultural land use density the higher incidence of intersex in smallmouth bass. The data appears to suggest beyond a certain density of agricultural land and/ or human population, the smallmouth bass population is impacted.

The USGS plans to work with the Chesapeake Bay Program to identify the chemicals that are causing the intersex, skin lesions and fish kills. The Chesapeake Bay Program intends to develop toxic contaminant reduction strategies to be added to the Chesapeake Bay TMDL by 2015. The impact on human life and the ecosystem of these and other emerging contaminants is not known, but now is the time to find out the impact from the substance we’ve been allowing to enter the waters of the earth. We need to determine the impact and fate of these micro pollutants before we implement the watershed cleanup plans to make sure we are implementing the right strategies for the health of the entire ecosystem which may include eliminating the use of certain chemicals and other actions.

Thursday, August 30, 2012

Hantavirus-Clean Up and Mouse Proof the House

Image of Deer Mouse taken from CDC 

I read in the paper the other day that seven Yosemite visitors have recently been stricken with Hantavirus. Three died. Hantaviruses are found in the droppings, urine and saliva of infected deer mice. Hantavirus pulmonary syndrome (HPS), the illness caused by the virus, can take 3 to 60 days to develop after exposure. Symptoms include fever, headache, muscle aches, vomiting and diarrhea. The syndrome is fatal in 30%-40% of all cases. There is no vaccine, treatment or cure for HPS. Hantavirus is typically transmitted by breathing in particles in the air from the droppings, urine and saliva of infected rodents. However, there have been a small number of reported cases of HPS believed to have been contracted through rodent bites. Since the virus was first identified in the United States in 1993, there have been 67 cases in California and 593 nationwide including along the Appalachian Trail possibly in Virginia. Rodents, themselves, neither get sick nor can they pass along the infection to other animals; however the Center for Disease Control, CDC, has identified the ability of Hantavirus to adapt to new rodent species. Although currently rare, HPS is potentially deadly and may be an emerging disease. Rodent control in and around the home (and Curry Village) remains the primary strategy for preventing Hantavirus infection.

Knowing about Hantavirus, I was distressed and disgusted upon returning from an extended trip in the first year we owned our home to discover mouse droppings in the pantry and utility room. My husband took care of the capture and removal and I took care of the safe cleanup and mouse proofing the house, while the cat provided monitoring, patrolling the house at night. The only comments I have on mouse capture is that peanut butter and walnuts are excellent bait for either the capture and release traps or the spring traps. It appears that mice love nuts and the ruined baking supplies provided excellent bait for my husband’s trapping. It took a while, but eventually the husband was able to rid the house of mice. Though at one point it seemed he would dump the mouse in the woods and it would sneak right back in through the gas pipe in the fireplace. Eventually, I managed to seal up all likely entries and we have been mouse free for a while, but annual maintenance is necessary to keep mice out of the house.

A mouse can fit through the narrowest gap, seemingly flattening themselves to crawl into the house. According to the Center for Disease Control a gap of a quarter of an inch or a hole the size of a pencil eraser is large enough for a mouse to enter. A systematic approach is best for sealing all entry points. First of all, there is no way to prevent mice from getting into the garage because garage doors just do not seal that tight in their tracks. Instead, it is necessary to keep all nesting material and clutter out of the garage and seal all entries to the house. If you keep your trash cans in the garage make sure that the can(s) has a tight lid and no holes in the can. The garage turned out to be an area of entry into our house. Because of a sloping lot that gives me a daylight basement, the top of the foundation is about 12 inches above the garage floor. A compressed layer of insulation had allowed the mice entry into the basement. Steel wool and lath screening was pushed into every crack, the area caulked and thanks to Larry Reed, carpenter extraordinaire, the garage was finished, trimmed and sealed. New weather stripping was placed on every exterior door. Lath screen was cut to fit around all the kitchen pipes, the dryer vent pipe, the gas pipe to the fireplace the pilot light and valve to the fireplace.  The space between the foundation and siding was carefully caulked and sealed. Attic vents were screened. Windows were caulked and weather stripping on the windows checked. All exterior  holes for electrical, plumbing, and gas lines were carefully sealed with Duxseal.

Do not sweep or vacuum up mouse urine, droppings, or nests. This will cause virus particles to go into the air, where they can be breathed in. To clean up the mouse dropping and my pantry, and utility room I first geared up. According to OSHA and the CDC if  there is not a heavy accumulation of droppings you need only  wear disposable protective clothing and gloves (neoprene, nitrile or latex-free), rubber boots and a disposable N95 respiratorto safely clean up rodent droppings. A N95 disposable respirator is just one of those white dust masks (look for the certification number and yes, I keep them in the house), I wore my rain boots and some old work cloths that I threw out afterwards. The first thing I did was throw out all the food  in the pantry and sprayed the shelf paper with disinfectant. Make sure you get the urine and droppings very wet. Let it soak for 5 minutes and then use paper towel to wipe up the urine and droppings and throw the paper towels into a plastic bag and seal carefully. I also removed the shelf paper and then cleaned the pantry again using disinfectant.

In the utility room I sprayed the floor and all flat surfaces including furnace ducts, modem shelf and top of the furnace, hot water heater and pressure tank with disinfectant, let it soak in for five minutes then used paper towels to wipe up all the droppings and then used a disposable swifter wet mop to mop the room. The basement was never cleaner. After cleanup is complete and all paper towels and swifter pads sealed in plastic bags, wash you gloved hands and boots with spray a disinfectant or a bleach solution before taking the gloves and boots off. Then throw the gloves out along with the clothes.  Wash hands with soap and warm water after taking off your gloves and take a nice hot shower before going to the store to buy new shelf paper and pantry staples. While at the store buy heavy plastic canisters to store grains, and baking supplies. 

Monday, August 27, 2012

The History of Drinking Water in Washington DC


In the first decade of the nineteenth century a group of residents of Washington DC were granted permission to pipe water from the city spring to their neighborhood in the 600 block of Pennsylvania Avenue. Shortly thereafter the city built a pipe to convey water from a city spring to the northwestern Pennsylvania Avenue vicinity, between 9th and 14th streets. These, were the first instances of water deliveries in Washington DC and the beginning of the water system in our nation’s capital. The city-wide delivery of fresh water was still another fifty years away and would arrive with the Washington Aqueduct.

The original portions of the Washington Aqueduct were planned and built by Lieutenant Montgomery C. Meigs of the Army Corp of Engineers. The Dalecarlia Reservoir was completed in 1858 and water first reached the District through the Washington Aqueduct system on January 3, 1859. Initially the reservoir provided water to the city from the adjacent Little Falls Branch, but this soon was inadequate and flow from the Potomac River was added in 1864. At that time the city government believed, the Washington Aqueduct system would be sufficient for all the future water needs of the city. Today the Washington Aqueduct is a division of the Baltimore District, U.S. Army Corps of Engineers. The Aqueduct is a federally owned and operated public water supply agency that produces an average of 180 million gallons of water per day at two treatment plants located in Washington DC and sells the water to the District of Columbia, Arlington County, Virginia, and the City of Falls Church, Virginia.

 After the initial construction of the Washington Aqueduct the surge in population of Washington DC during the Civil War, quickly created a human waste problem in the city and there were epidemics of smallpox, malaria, and typhoid from human waste contaminating the water supply which took many thousands of lives during the war years. Dr. John Snow had discovered and proved the connection between cholera and contaminated water during the 1850’s in London, England. Nonetheless, the general belief was that if water looked, tasted and smelled fine it was good and though the Potomac River provided dilution disease survived. The Washington Aqueduct was originally built as a water transportation system, to bring the river water into the city. However, in 1895 the flow from Little Falls Branch was diverted away from the Dalecarlia Reservoir to prevent disease in conjunction with development of the sanitary sewer system. Despite these steps it was clear that, the Washington Aqueduct needed to be expanded and have a filtration system. The Washington Reservoir, which is now called the McMillan Reservoir, was built in 1902 to increase supply and in 1905, a 75 million gallon per day slow-sand filtration system was added at that reservoir and the Bryant Street high-lift pumping station was built.

After World War I an 80 million gallon per day rapid-sand filter was added at the Dalecarlia Reservoir to address the problems created by continued population growth and the sheer amount of raw sewage that was being pumped into the river. Primary waste treatment began for Washington DC at Blue Plains sewage treatment plant in 1937. The continuous population growth of Washington DC during World War II made it necessary to continue to expand and improve the water supply system. In February 1946, Congress approved comprehensive plans from the Army Corp of Engineers and the City Engineer to construct, improve and add to the existing water system. For more than thirty years, implementation of the plan underwent periodic modifications through changing requirements and increases in necessary funding by Congress. This awkward and inefficient oversight and funding was still in effect when I briefly lived in the District in the early 1970s when the water and sewage agency was known as the District of Columbia Department of Environmental Services. Later, in 1985, the District Government established a new Department of Public Works, of which the Water and Sewer Administration was a part of until 1996.

In 1996, the District Government initiated the creation of the District of Columbia Water and Sewer Authority (DC WASA re-branded DC Water in 2010), an independent authority of the District of Columbia providing water delivery and sewage services to the region. On April 18, 1996, following a 30-day Congressional review period, the District Council enacted DC Law 11-111, "The Water and Sewer Authority Establishment and Department of Public Works Reorganization Act of 1996." This allowed DC WASA to have a separate and dedicated source of funding-water and sewer rates. It was envisioned that DC WASA would then be able to use that funding to meet its statutory obligation to provide sanitary sewer services and deliver potable water to the Washington Metropolitan Area. The Washington Aqueduct remains   federally owned.

Today, the Aqueduct draws water from the Potomac River at the Great Falls and Little Falls intakes and treats the water at two treatment plants, Dalecarlia and McMillan. The Aqueduct filters and disinfects water from the Potomac River to meet current safe drinking water standards. The treatment process includes sedimentation, filtration, fluoridation, pH adjustment, primary disinfection using free chlorine, secondary disinfection with chloramine through the addition of ammonia, and corrosion control with orthophosphate. The EPA sets national limits on residual disinfectant levels in drinking water to reduce the risk of exposure to disinfection byproducts formed when public water systems add chemical disinfectant for either primary or residual treatment. These levels are known as Maximum Residual Disinfectant Levels (MRDLs). The EPA also sets EPA sets limits on the contaminants regulated under the Safe Drinking Water Act to ensure that the water is safe for human consumption. These limits are known as Maximum Contaminant Levels (MCLs). During calendar year 2011, no MRDL nor any MCL violations occurred in the Washington Aqueduct system.

By 1996 some portions of the water delivery system were 100 years old and the sewage system was almost the same age. The water and sewage rates in place in the Washington Metropolitan Area covered the costs to deliver the water and treat the sewage and replace 0.33% of the system each year, an unrealistic and irresponsible repair and replacement rate.  DC Water averages between 400 and 500 water main breaks per year, and they thought that a plan to replace the system over a 300 year time span was meeting their statutory obligations. 

Water delivery systems have a long life span, they are just pipes, pumps and valves, but the life span is not infinite. We reward short sighted behavior. In order to have cheaper water and sewer, a replacement cost schedule was not built into the customer rates for the past 78 years which coincidentally is the current average age of a water main in Washington DC. There are water pipes north of the White House that are reported to have been laid before the Civil War. This past Spring DC Water announced that they have tripled the replacement rate to 1% (with of course the increase in water rates) so that in 100 years the system will be replaced. Sewage rates were increased to finance the District’s portion of the $7.8 billion Blue Plains improvement program called the Clean Rivers Project that will meet the reduced total nitrogen released requirements of their operating permits and increase the control of the system during rain storms in addition sludge treatment will be improved and sewer piping improved in many areas. In truth, according to an interview with the General Manager, George Hawkins on National Public Radio, DC Water has gotten so far behind that they cannot to catch up- it will take decades. It is likely, given the age of the water system in Washington DC the increase in replacement rate was probably necessary to address what was failing each year. One hundred years is longer than the predicated life of a water distribution system, piping systems are rated at 80 years and the average water main in Washington DC is 78 years old. The water pipes in DC are old. They leak. DC Water is trying to use a predictive modeling to determine which pipes need to replace first to keep the good quality* water they are buying from the Washington Aqueduct flowing to the homes and businesses in the District.

Washington DC (and most of America) has always thought about the cost of water wrong, there should have always been a plan for maintenance, upgrade and replacement of the system and the care and protection the water resources; instead we have all taken water (and sewage) for granted. Every pipe should have been on a schedule to be replaced before it exceeded its life and broke. The water rates need to cover these capital replacement and maintenance costs. If we do not maintain our infrastructure we will not have on demand water. DC Water sees persuading customers to pay for the maintenance and improvement of the water and sewer system as their biggest challenge. The investment into water and sewer infrastructure is simply one of the best investments that any community can make.

* Dr. Marc Edwards a professor of engineering at Virginia Tech discovered while doing research in the mid-1990s to identify the cause of an increasing incidence of pinhole leaks in copper water pipes, that chloramine was causing the accelerated pipe deterioration and extreme lead concentrations in DC drinking water. Chloramine-treated water picks up lead from pipes and solder and does not release it, resulting in elevated levels and deterioration of the pipes. The change to chloramine was made after the EPA issued regulations concerning disinfection by-products formed when chlorine reacts with organic matter in drinking water; the EPA considered these byproducts to be a potential health threat. Chloramines do not produce disinfection byproducts. The lead problem was addressed in 2004 by the Washington Aqueduct adding additional treatment steps to the water to prevent the chloramine from dissolving lead in the water mains, solder joints, and fixtures. In addition, DC WASA spent $97 million to replace a portion of 15,000 pipes and 2,000 full pipe replacements. Then after the dust settled on this re-branded themselves as DC Water. 

Thursday, August 23, 2012

EPA Rule Targeting Coal Power Plants Voided by Court

On Tuesday the U.S. Court of Appeals for the District of Columbia ruled (2-1) that the Cross State Air Pollution Rule, CSAPR, exceeded the U.S. Environmental Protection Agency’s authority by requiring some state to clean up more than their fair share of pollution. CSAPR defined each State’s emissions reduction goals and the Federal Implementation Plans to obtain those goals at the State level. However, the EPA had used computer modeling to generate emissions “budgets” for each upwind State without regard for the amount of pollution each state was contributing to a downwind problem, but based instead on the cost of remediation. The EPA was requiring the level of cleanup to be based on cost and requiring more work to be done where the cost of capturing a ton of sulfur-dioxide and nitrogen-oxide was the lowest creating a pollution trading system.

CSAPR, requiring reductions of sulfur-dioxide and nitrogen-oxide emissions in coal fired plants, was intended to have gone into effect on January 1, 2012, but the U.S. Court of Appeals District of Columbia Circuit granted a stay to the implementation of the CSAPR pending resolution of the legal challenges. Now the Court of Appeals has found the rule exceeded EPA authority. CSAPR, if it had been implemented would have reduce SO2 emissions by 73% from 2005 levels and NOx emissions by 54% at the approximately 1,000 coal fired electrical generation plants in the eastern half of the country. This rule was intended to help downwind states attain the 24-Hour and/or Annual PM2.5 National Ambient Air Quality Standards (NAAQS) and the 1997 8-Hour Ozone NAAQS. CSAPR would have replace EPA's 2005 Clean Air Interstate Rule (CAIR) which will now remain in effect. Both these rules are intended to allow states to better control their particulate pollution.

According to the Lung Association, the two biggest air pollution threats in the United States are ozone and particle pollution. Other pollutants include carbon monoxide, lead, nitrogen dioxide, sulfur dioxide and a variety of toxic substances including mercury that appear in smaller quantities. The EPA requires states to monitor air pollution under the NAAQS to assess the healthfulness of air quality and ensure that they meet minimum air quality standards. One standard of NAAQS is particulate pollution of 2.5 micrometers or less called PM2.5. Combustion engines and coal burning power plants are key contributors to PM2.5 particles, and according to the US EPA and World Health Organization, the smaller, finer pollutants measured by PM2.5 are especially dangerous for human health. Studies have shown that people are at increased risk of asthma, lung cancer, cardiovascular problems, birth defects and premature death from particles smaller than 2.5 microns in diameter that lodge deep in the lungs.

CASPR was intended to prevent pollution from one state from moving into other states and preventing them from meeting their air quality goals. Several states have been unable to meet the current particulate standard. PM2.5 particles can be either directly emitted or formed via atmospheric reactions. Primary particles are emitted from cars, trucks, and heavy equipment, as well as residential wood combustion, forest fires, and agricultural waste burning. The main components of secondary particulate matter are formed when pollutants like NOx and SO2 react in the atmosphere to form particles.

Currently, under the Clean Air Act the US EPA has established both annual and 24-hour PM2.5 air quality standards (as well as standards for other pollutants). The annual standard is 15 ug/m3 (an air quality index, AQI of 49). The 24-hr standard is 35 ug/m3 (an AQI of 99). In June of 2012 EPA announced that they are proposing stricter air quality particulate standards to go into effect in December 2012. The standard is anticipated to be 12-13 ug/m3. According to American Lung Association State of the Air Report, Pittsburgh, PA had the highest particle pollution in the nation on an annual basis. Seven cities averaged particulate levels higher than the 15 ug/m3 current standard allows: Bakersfield, CA; Hanford, CA; Los Angeles, CA; Visalia, CA; Fresno, CA; Pittsburgh, PA; and Phoenix, AZ. The American Lung Association in their latest report states that twenty cities actually have average year-round particle pollution below the current regulated level, but above the proposed EPA air quality standard of 12-13 ug/m3. The maximum 24 hour standard will remain unchanged at 35 ug/m3. While particulate pollution remains a problem the EPA has not been able to address the problem by regulation targeted at coal fired power plants.

The earth’s atmosphere is interconnected. That is accepted when it comes to carbon dioxide, but it also applies to industrial pollutants and soot. The EPA has estimated that just one-quarter of U.S. measured pollution emissions from coal-burning power plants are deposited within the contiguous U.S. The remainder enters the global cycle. Conversely, current estimates are that less than half of all measured coal pollution emissions deposited within the United States comes from American sources. According to the Mount Bachelor Observatory, Chinese exports include acid rain that falls in China, Korea, and Japan, and pollutants that enter the air stream including sulfates, NOx, black carbon, soot produced by cars, stoves, factories, and crop burning.